Parameter extraction of resistive thermal sensors
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
47 | en_US |
dc.citation.issue |
1 | en_US |
dc.citation.spage |
43 | en_US |
dc.citation.volume |
55 | en_US |
dc.contributor.author |
Chen, YM | en_US |
dc.contributor.author |
Shie, JS | en_US |
dc.contributor.author |
Hwang, T | en_US |
dc.contributor.department |
交大名義發表 | zh_TW |
dc.contributor.department |
光電工程學系 | zh_TW |
dc.contributor.department |
National Chiao Tung University | en_US |
dc.contributor.department |
Department of Photonics | en_US |
dc.date.accessioned |
2014-12-08T15:02:30Z | |
dc.date.available |
2014-12-08T15:02:30Z | |
dc.date.issued |
1996-07-15 | en_US |
dc.description.abstract |
Obtaining thermal parameters is important in evaluating the performance of thermal microsensors. Two experimental methods are described here for the study of the pressure-dependent thermal behavior of the sensors: a bolometric method that utilizes a chopped light input to obtain a sensor frequency response, and deriving its thermal data therefrom; a d.c, electrical method that measures the heat required for balance under d.c. bias, and obtaining sensor information. The thermal conductance and capacitance, absorptance, as well as emissivity of a sensor can be extracted from the experimental measurements. These parameters provide the essential data for the electrothermal SPICE program in the related design simulations. | en_US |
dc.identifier.doi |
10.1016/S0924-4247(96)01248-4 | en_US |
dc.identifier.issn |
0924-4247 | en_US |
dc.identifier.journal |
SENSORS AND ACTUATORS A-PHYSICAL | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1016/S0924-4247(96)01248-4 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/1167 | |
dc.identifier.wosnumber |
WOS:A1996VY35800009 | |
dc.language.iso |
en_US | en_US |
dc.subject |
thermal sensors | en_US |
dc.subject |
parameter extraction | en_US |
dc.subject |
bolometric method | en_US |
dc.subject |
dc method | en_US |
dc.title |
Parameter extraction of resistive thermal sensors | en_US |
dc.type |
Article; Proceedings Paper | en_US |