Fabrication of microfluidic devices using dry film photoresist for microchip capillary electrophoresis
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
271 | en_US |
dc.citation.issue |
2 | en_US |
dc.citation.spage |
267 | en_US |
dc.citation.volume |
1111 | en_US |
dc.contributor.author |
Tsai, YC | en_US |
dc.contributor.author |
Jen, HP | en_US |
dc.contributor.author |
Lin, KW | en_US |
dc.contributor.author |
Hsieh, YZ | en_US |
dc.contributor.department |
應用化學系 | zh_TW |
dc.contributor.department |
Department of Applied Chemistry | en_US |
dc.date.accessioned |
2014-12-08T15:16:51Z | |
dc.date.available |
2014-12-08T15:16:51Z | |
dc.date.issued |
2006-04-14 | en_US |
dc.description.abstract |
An inexpensive, disposable microfluidic device was fabricated from a dry film photoresist using a combination of photolithographic and hot roll lamination techniques. A microfluidic flow pattern was prefabricated in a dry film photoresist tape using traditional photolithographic methods. This tape became bonded to a poly(methyl methacrylate) (PMMA) sheet with prepouched holes when passed through a hot roll laminator. A copper working electrode and platinum decoupler was readily incorporated within this microchip. The integrated microchip device was then fixed in a laboratory-built Plexiglas holder prior to its use in microchip capillary electrophoresis. The performance of this device with amperometric detection for the separation of dopamine and catechol was examined. The separation was complete within 50 s at an applied potential of 200 V/cm. The relative standard deviations (RSD) of analyte migration times were less than 0.71%, and the theoretical plate numbers for dopamine and catechol were 3.2 x 10(4) and 4.1 x 10(4), respectively, based on a 65 min separation channel. (c) 2005 Elsevier B.V. All rights reserved. | en_US |
dc.identifier.doi |
10.1016/j.chroma.2005.12.003 | en_US |
dc.identifier.issn |
0021-9673 | en_US |
dc.identifier.journal |
JOURNAL OF CHROMATOGRAPHY A | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1016/j.chroma.2005.12.003 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/12381 | |
dc.identifier.wosnumber |
WOS:000236656300022 | |
dc.language.iso |
en_US | en_US |
dc.subject |
microchip capillary electrophoresis | en_US |
dc.subject |
amperometric detection | en_US |
dc.subject |
dry film photoresist | en_US |
dc.subject |
microfluidic devices | en_US |
dc.title |
Fabrication of microfluidic devices using dry film photoresist for microchip capillary electrophoresis | en_US |
dc.type |
Article; Proceedings Paper | en_US |
檔案
- 000236656300022.pdf (341.0 KB, Adobe PDF)
所屬典藏: 會議論文
引用此條目
Tsai, Y., Jen, H., Lin, K., & Hsieh, Y. (2006). Fabrication of microfluidic devices using dry film photoresist for microchip capillary electrophoresis. JOURNAL OF CHROMATOGRAPHY A, 1111(2), 267–271. https://doi.org/10.1016/j.chroma.2005.12.003
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/12381