AC power loss and signal coupling in very large scale integration backend interconnects
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
2996 | en_US |
dc.citation.issue |
4B | en_US |
dc.citation.spage |
2992 | en_US |
dc.citation.volume |
45 | en_US |
dc.contributor.author |
Chen, CC | en_US |
dc.contributor.author |
Kao, HL | en_US |
dc.contributor.author |
Liao, CC | en_US |
dc.contributor.author |
Chin, A | en_US |
dc.contributor.author |
McAlister, SP | en_US |
dc.contributor.author |
Chi, CC | en_US |
dc.contributor.department |
電子工程學系及電子研究所 | zh_TW |
dc.contributor.department |
Department of Electronics Engineering and Institute of Electronics | en_US |
dc.date.accessioned |
2014-12-08T15:16:56Z | |
dc.date.available |
2014-12-08T15:16:56Z | |
dc.date.issued |
2006-04-01 | en_US |
dc.description.abstract |
Both the coupling and AC power losses in integrated circuit interconnects in the radio-frequency regime have been measured. The AC power loss decreases with decreasing length, decreasing spacing, and increasing inter metal dielectric (IMD) thickness of parallel metal lines. The unwanted signal coupling and cross-talk monotonically decrease with increasing spacing and decreasing length of the parallel metal lines. However, increasing the IMD thickness from 0.7 to 6 mu m improves the low frequency performance but not the maximum operation frequency. Using a high-resistivity Si (HRS) substrate the AC power loss is significantly reduced but is traded off with an increase in coupling loss. The most effective method of reducing both the AC power and coupling losses is the combined use of three dimensional (3D) integration and an HRS, which gives larger than 1-2 orders of magnitude improvement, up to 20 GHz. | en_US |
dc.identifier.doi |
10.1143/JJAP.45.2992 | en_US |
dc.identifier.issn |
0021-4922 | en_US |
dc.identifier.journal |
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1143/JJAP.45.2992 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/12413 | |
dc.identifier.wosnumber |
WOS:000237570600021 | |
dc.language.iso |
en_US | en_US |
dc.subject |
AC power | en_US |
dc.subject |
interconnect | en_US |
dc.subject |
RF | en_US |
dc.subject |
Si | en_US |
dc.subject |
3D | en_US |
dc.title |
AC power loss and signal coupling in very large scale integration backend interconnects | en_US |
dc.type |
Article; Proceedings Paper | en_US |
檔案
- 000237570600021.pdf (735.4 KB, Adobe PDF)
所屬典藏: 會議論文
引用此條目
Chen, C., Kao, H., Liao, C., Chin, A., McAlister, S., & Chi, C. (2006). AC power loss and signal coupling in very large scale integration backend interconnects. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 45(4B), 2992–2996. https://doi.org/10.1143/JJAP.45.2992
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/12413