AMPFLUID: Aggregation Magnified Post-Assay Fluorescence for Ultrasensitive Immunodetection on Digital Microfluidics
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
235 | en_US |
dc.citation.spage |
225 | en_US |
dc.citation.volume |
103 | en_US |
dc.citation.woscount |
0 | en_US |
dc.contributor.author |
Huang, Cheng-Yeh | en_US |
dc.contributor.author |
Shih, Po-Huai | en_US |
dc.contributor.author |
Tsai, Po-Yen | en_US |
dc.contributor.author |
Lee, I-Chin | en_US |
dc.contributor.author |
Hsu, Hsin-Yun | en_US |
dc.contributor.author |
Huang, Hong-Yuan | en_US |
dc.contributor.author |
Fan, Shih-Kang | en_US |
dc.contributor.author |
Hsu, Wensyang | en_US |
dc.contributor.department |
機械工程學系 | zh_TW |
dc.contributor.department |
應用化學系 | zh_TW |
dc.contributor.department |
Department of Mechanical Engineering | en_US |
dc.contributor.department |
Department of Applied Chemistry | en_US |
dc.date.accessioned |
2015-07-21T08:28:30Z | |
dc.date.available |
2015-07-21T08:28:30Z | |
dc.date.issued |
2015-02-01 | en_US |
dc.description.abstract |
Several strategies are currently employed to enhance the detection limit of bead-based assays, but all these approaches improve the sensitivity by varying the assay procedures chemically or biologically. In previous digital microfluidic setups for bead-based immunoassay, the magnetic beads were suspended for detection. We investigated the effect of bead aggregation in such an immunoassay system and propose the aggregation magnified post-assay fluorescence for ultrasensitive immunodetection on digital microfluidics (AMPFLUID). The detection signal and sensitivity are further enhanced even at the post-assay stage without altering the original assay protocol on employing magnetically triggered post-assay aggregation of beads in a digital microfluidic setup followed by processing of the fluorescent signal. This method is shown to enhance the fluorescent signal with increased consistency and sensitivity after appropriate charge-coupled device (CCD) calibration. This method of on-chip detection allows the fulfilment of consumption of a volume at the nanoliter level and a limit of detection in the range picogram/mL. In our sTNF-RI model immunoassay, only 2.5 nL of sample is required; a detection limit 15 pg/mL is achieved. The decreased uncertainty of the measure is indicated by the error bars and coefficient of variation. | en_US |
dc.identifier.doi |
10.1109/JPROC.2014.2376967 | en_US |
dc.identifier.issn |
0018-9219 | en_US |
dc.identifier.journal |
PROCEEDINGS OF THE IEEE | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1109/JPROC.2014.2376967 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/124572 | |
dc.identifier.wosnumber |
WOS:000352156900008 | en_US |
dc.language.iso |
en_US | en_US |
dc.subject |
Aggregation | en_US |
dc.subject |
bead-based immunoassay | en_US |
dc.subject |
concentration | en_US |
dc.subject |
digital microfluidic (DMF) | en_US |
dc.subject |
electrowetting on dielectric (EWOD) | en_US |
dc.subject |
electrowetting | en_US |
dc.subject |
immunoassay | en_US |
dc.subject |
immunochip | en_US |
dc.subject |
lab-on-a-chip | en_US |
dc.subject |
magnetic beads | en_US |
dc.subject |
micro total analysis system (mu TAS) | en_US |
dc.subject |
microfluidics | en_US |
dc.title |
AMPFLUID: Aggregation Magnified Post-Assay Fluorescence for Ultrasensitive Immunodetection on Digital Microfluidics | en_US |
dc.type |
Article | en_US |
檔案
本條目沒有附加檔案。
所屬典藏: 期刊論文
引用此條目
Huang, C.-Y., Shih, P.-H., Tsai, P.-Y., Lee, I.-C., Hsu, H.-Y., Huang, H.-Y., Fan, S.-K., & Hsu, W. (2015). AMPFLUID: Aggregation Magnified Post-Assay Fluorescence for Ultrasensitive Immunodetection on Digital Microfluidics. PROCEEDINGS OF THE IEEE, 103, 225–235. https://doi.org/10.1109/JPROC.2014.2376967
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/124572