Development of LabVIEW Based Micro Computed Tomography System on Vertical Rotary Gantry
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
276 | en_US |
dc.citation.spage |
273 | en_US |
dc.citation.volume |
45 | en_US |
dc.citation.woscount |
0 | en_US |
dc.contributor.author |
Tu, Shih-Huan | en_US |
dc.contributor.author |
Chen, Ya-Chen | en_US |
dc.contributor.author |
Hsiao, Tzu-Chien | en_US |
dc.contributor.author |
Jin, Shih-Chun | en_US |
dc.contributor.author |
Chen, Jyh-Cheng | en_US |
dc.contributor.department |
分子醫學與生物工程研究所 | zh_TW |
dc.contributor.department |
資訊工程學系 | zh_TW |
dc.contributor.department |
Institute of Molecular Medicine and Bioengineering | en_US |
dc.contributor.department |
Department of Computer Science | en_US |
dc.date.accessioned |
2015-07-21T08:30:51Z | |
dc.date.available |
2015-07-21T08:30:51Z | |
dc.date.issued |
2015-01-01 | en_US |
dc.description.abstract |
Construction of a micro computed tomography (micro-CT) system has been proposed and developed in recent years. For the need of exploring and investigating a novel computed tomography (CT) image reconstruction method, custom-built micro-CT system offers a corresponding laboratory research environment. To develop a controllable program capable of incorporating with different devices efficiently, we use Laboratory Virtual Instrumentation Engineering Workbench (LabVIEW), a graphical programming language, as our programming environment to implement micro-CT system on vertical rotary gantry. We scanned and reconstructed the 360 projections derived from full 360 degrees scan with angular stepping of 1 degrees. Total scan time is about 9.1 minutes. We will combine micro fluorescence tomography (micro-FT) and micro-CT on uni-platform in the future. | en_US |
dc.identifier.doi |
10.1007/978-3-319-11128-5_68 | en_US |
dc.identifier.isbn |
978-3-319-11127-8 | en_US |
dc.identifier.issn |
1680-0737 | en_US |
dc.identifier.journal |
6TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1007/978-3-319-11128-5_68 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/124980 | |
dc.identifier.wosnumber |
WOS:000349454200068 | en_US |
dc.language.iso |
en_US | en_US |
dc.subject |
micro-CT system | en_US |
dc.subject |
LabVIEW | en_US |
dc.subject |
vertical rotary gantry system | en_US |
dc.title |
Development of LabVIEW Based Micro Computed Tomography System on Vertical Rotary Gantry | en_US |
dc.type |
Proceedings Paper | en_US |
檔案
本條目沒有附加檔案。
所屬典藏: 會議論文
引用此條目
Tu, S.-H., Chen, Y.-C., Hsiao, T.-C., Jin, S.-C., & Chen, J.-C. (2015). Development of LabVIEW Based Micro Computed Tomography System on Vertical Rotary Gantry. 6TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 45, 273–276. https://doi.org/10.1007/978-3-319-11128-5_68
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/124980