An Effective Arterial Blood Pressure Signal Processing System Based on EEMD Method
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.woscount |
0 | en_US |
dc.contributor.author |
Chuang, Shang-Yi | en_US |
dc.contributor.author |
Liao, Jia-Ju | en_US |
dc.contributor.author |
Chou, Chia-Ching | en_US |
dc.contributor.author |
Chang, Chia-Chi | en_US |
dc.contributor.author |
Fang, Wai-Chi | en_US |
dc.contributor.department |
電子工程學系及電子研究所 | zh_TW |
dc.contributor.department |
Department of Electronics Engineering and Institute of Electronics | en_US |
dc.date.accessioned |
2015-12-02T03:00:49Z | |
dc.date.available |
2015-12-02T03:00:49Z | |
dc.date.issued |
2014-01-01 | en_US |
dc.description.abstract |
This study proposed an effective signal processing system based on Ensemble Empirical Mode Decomposition (EEMD) method for the analysis of arterial blood pressure (ABP). The whole system was implemented on an ARM-based SoC development platform to attain the on-line non-stationary signal processing. A non-invasive blood pressure acquisition device (NIBP100D) was used to record the continuous ABP as the input signal. According to the non-stationary characteristics of ABP, EEMD is useful to achieve accurate decomposition for ABP spectral analysis. The signal was decomposed into several Intrinsic Mode Functions (IMFs) by EEMD, and quantitatively assessed by fast Fourier transform (FFT). The results showed that the proposed EEMD processor can effectively solve the mode mixing problem of Empirical Mode Decomposition (EMD) and the FFT spectrum of IMF5, IMF6, and IMF7 to reveal heart rate and respiration. | en_US |
dc.identifier.isbn |
978-1-4799-2776-0 | en_US |
dc.identifier.issn |
en_US | |
dc.identifier.journal |
2014 INTERNATIONAL SYMPOSIUM ON VLSI DESIGN, AUTOMATION AND TEST (VLSI-DAT) | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/128470 | |
dc.identifier.wosnumber |
WOS:000356616400026 | en_US |
dc.language.iso |
en_US | en_US |
dc.subject |
ensemble empirical mode decomposition | en_US |
dc.subject |
arterial blood pressure | en_US |
dc.subject |
FPGA | en_US |
dc.subject |
continuous blood pressure | en_US |
dc.title |
An Effective Arterial Blood Pressure Signal Processing System Based on EEMD Method | en_US |
dc.type |
Proceedings Paper | en_US |
檔案
本條目沒有附加檔案。
所屬典藏: 會議論文
引用此條目
Chuang, S.-Y., Liao, J.-J., Chou, C.-C., Chang, C.-C., & Fang, W.-C. (2014). An Effective Arterial Blood Pressure Signal Processing System Based on EEMD Method. 2014 INTERNATIONAL SYMPOSIUM ON VLSI DESIGN, AUTOMATION AND TEST (VLSI-DAT). https://ir.lib.nycu.edu.tw/handle/11536/128470
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/128470