Voltage Source Inverter Drive Using Error-compensated Pulse Width Modulation
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
397 | en_US |
dc.citation.spage |
388 | en_US |
dc.citation.volume |
16 | en_US |
dc.citation.woscount |
0 | en_US |
dc.contributor.author |
Chen, Keng-Yuan | en_US |
dc.contributor.author |
Hu, Jwu-Sheng | en_US |
dc.contributor.author |
Lin, Jau-Nan | en_US |
dc.contributor.department |
電控工程研究所 | zh_TW |
dc.contributor.department |
Institute of Electrical and Control Engineering | en_US |
dc.date.accessioned |
2016-03-28T00:04:27Z | |
dc.date.available |
2016-03-28T00:04:27Z | |
dc.date.issued |
2016-01-01 | en_US |
dc.description.abstract |
An error-compensated pulse width modulator (ECPWM) is proposed to improve the baseband harmonic performance and the switching loss of voltage source inverters (VSIs). Selecting between harmonic distortion and switching loss is a design tradeoff in the conventional space vector pulse width modulation. In this work, an accumulated difference in produced and desired phase voltages is considered to adjust the reference signal. This mechanism can compensate for the voltage error in the previous carrier period. With error compensation every half-carrier period, the proposed ECPWM allows one-half reduction in carrier frequency without scarifying baseband harmonic distortion. The proposed modulator is applied to a three-phase VSI with R-L load and a motor-speed-control system for experiments. The measured efficiency and operating temperature of switches confirm the effectiveness of the proposed scheme. | en_US |
dc.identifier.doi |
10.6113/JPE.2016.16.1.388 | en_US |
dc.identifier.issn |
1598-2092 | en_US |
dc.identifier.journal |
JOURNAL OF POWER ELECTRONICS | en_US |
dc.identifier.uri |
http://dx.doi.org/10.6113/JPE.2016.16.1.388 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/129701 | |
dc.identifier.wosnumber |
WOS:000368383100039 | en_US |
dc.language.iso |
en_US | en_US |
dc.subject |
Digital signal | en_US |
dc.subject |
Motor drive | en_US |
dc.subject |
Pulse-width modulation (PWM) | en_US |
dc.subject |
Space-vector PWM | en_US |
dc.subject |
Voltage-source inverter | en_US |
dc.title |
Voltage Source Inverter Drive Using Error-compensated Pulse Width Modulation | en_US |
dc.type |
Article | en_US |
檔案
本條目沒有附加檔案。
所屬典藏: 期刊論文
引用此條目
Chen, K.-Y., Hu, J.-S., & Lin, J.-N. (2016). Voltage Source Inverter Drive Using Error-compensated Pulse Width Modulation. JOURNAL OF POWER ELECTRONICS, 16, 388–397. https://doi.org/10.6113/JPE.2016.16.1.388
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/129701