Control of VOCs emissions by condenser pre-treatment in a semiconductor fab
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
14 | en_US |
dc.citation.issue |
1-3 | en_US |
dc.citation.spage |
9 | en_US |
dc.citation.volume |
120 | en_US |
dc.citation.woscount |
5 | |
dc.contributor.author |
Lin, YC | en_US |
dc.contributor.author |
Chang, FT | en_US |
dc.contributor.author |
Bai, HL | en_US |
dc.contributor.author |
Pei, BS | en_US |
dc.contributor.department |
環境工程研究所 | zh_TW |
dc.contributor.department |
電子工程學系及電子研究所 | zh_TW |
dc.contributor.department |
Institute of Environmental Engineering | en_US |
dc.contributor.department |
Department of Electronics Engineering and Institute of Electronics | en_US |
dc.date.accessioned |
2014-12-08T15:19:21Z | |
dc.date.available |
2014-12-08T15:19:21Z | |
dc.date.issued |
2005-04-11 | en_US |
dc.description.abstract |
The performance of a modified design of local condensers to pre-treat a variety of volatile organic compounds (VOCs) emitted from the stripping process of a semiconductor fab was tested in this study. The reaction temperature of the condensers was controlled at around 10 degrees C, it is relatively higher than the traditional condenser reaction temperature. Both VOCs and water vapors were condensed and formed liquid films. This resulted in an enhancement of the VOCs removals, especially for VOCs of high boiling points or solubility. This can help to prevent the follow up zeolite concentrator from damage. The performance of the integrated system of condenser/zeolite concentrator could, therefore, remain highly efficient for a longer operation time. Its annualized cost would also be lower than installing the zeolite concentrator only. (c) 2005 Elsevier B.V. All rights reserved. | en_US |
dc.identifier.doi |
10.1016/j.jhazmat.2004.12.035 | en_US |
dc.identifier.issn |
0304-3894 | en_US |
dc.identifier.journal |
JOURNAL OF HAZARDOUS MATERIALS | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1016/j.jhazmat.2004.12.035 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/13818 | |
dc.identifier.wosnumber |
WOS:000228672200002 | |
dc.language.iso |
en_US | en_US |
dc.subject |
volatile organic compounds | en_US |
dc.subject |
DMDS | en_US |
dc.subject |
DMS | en_US |
dc.subject |
adsorbent | en_US |
dc.subject |
semiconductor | en_US |
dc.subject |
optoelectronic industry | en_US |
dc.subject |
TFT-LCD | en_US |
dc.title |
Control of VOCs emissions by condenser pre-treatment in a semiconductor fab | en_US |
dc.type |
Article | en_US |
檔案
- 000228672200002.pdf (234.5 KB, Adobe PDF)
所屬典藏: 期刊論文
引用此條目
Lin, Y., Chang, F., Bai, H., & Pei, B. (2005). Control of VOCs emissions by condenser pre-treatment in a semiconductor fab. JOURNAL OF HAZARDOUS MATERIALS, 120(1-3), 9–14. https://doi.org/10.1016/j.jhazmat.2004.12.035