Dilution and Mixing Algorithms for Flow-Based Microfluidic Biochips
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
627 | en_US |
dc.citation.spage |
614 | en_US |
dc.citation.volume |
36 | en_US |
dc.contributor.author |
Bhattacharjee, Sukanta | en_US |
dc.contributor.author |
Poddar, Sudip | en_US |
dc.contributor.author |
Roy, Sudip | en_US |
dc.contributor.author |
Huang, Juinn-Dar | en_US |
dc.contributor.author |
Bhattacharya, Bhargab B. | en_US |
dc.contributor.department |
電子工程學系及電子研究所 | zh_TW |
dc.contributor.department |
Department of Electronics Engineering and Institute of Electronics | en_US |
dc.date.accessioned |
2018-08-21T05:53:55Z | |
dc.date.available |
2018-08-21T05:53:55Z | |
dc.date.issued |
2017-04-01 | en_US |
dc.description.abstract |
Albeit sample preparation is well-studied for digital microfluidic biochips, very few prior work addressed this problem in the context of continuous-flow microfluidics from an algorithmic perspective. In the latter class of chips, microvalves and micropumps are used to manipulate on-chip fluid flow through microchannels in order to execute a biochemical protocol. Dilution of a sample fluid is a special case of sample preparation, where only two input reagents (commonly known as sample and buffer) are mixed in a desired volumetric ratio. In this paper, we propose a satisfiability-based dilution algorithm assuming the generalized mixing models supported by an N-segment, continuous-flow, rotary mixer. Given a target concentration and an error limit, the proposed algorithm first minimizes the number of mixing operations, and subsequently, reduces reagent-usage. Simulation results demonstrate that the proposed method outperforms existing dilution algorithms in terms of mixing steps (assay time) and waste production, and compares favorably with respect to reagent-usage (cost) when 4- and 8-segment rotary mixers are used. Next, we propose two variants of an algorithm for handling the open problem of k-reagent mixture-preparation (k >= 3) with an N-segment continuous-flow rotary mixer, and report experimental results to evaluate their performance. A software tool called flow-based sample preparation algorithm has also been developed that can be readily used for running the proposed algorithms. | en_US |
dc.identifier.doi |
10.1109/TCAD.2016.2597225 | en_US |
dc.identifier.issn |
0278-0070 | en_US |
dc.identifier.journal |
IEEE TRANSACTIONS ON COMPUTER-AIDED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1109/TCAD.2016.2597225 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/145333 | |
dc.identifier.wosnumber |
WOS:000398824500008 | en_US |
dc.language.iso |
en_US | en_US |
dc.subject |
Flow-based microfluidic biochip | en_US |
dc.subject |
sample preparation | en_US |
dc.subject |
satisfiability | en_US |
dc.title |
Dilution and Mixing Algorithms for Flow-Based Microfluidic Biochips | en_US |
dc.type |
Article | en_US |
檔案
本條目沒有附加檔案。
所屬典藏: 期刊論文