Terahertz Reflection-Mode Biological Imaging Based on InP HBT Source and Detector
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
283 | en_US |
dc.citation.spage |
274 | en_US |
dc.citation.volume |
7 | en_US |
dc.contributor.author |
Yun, Jongwon | en_US |
dc.contributor.author |
Oh, Seung Jae | en_US |
dc.contributor.author |
Song, Kiryong | en_US |
dc.contributor.author |
Yoon, Daekeun | en_US |
dc.contributor.author |
Son, Hye Young | en_US |
dc.contributor.author |
Choi, Yuna | en_US |
dc.contributor.author |
Huh, Yong-Min | en_US |
dc.contributor.author |
Rieh, Jae-Sung | en_US |
dc.contributor.department |
交大名義發表 | zh_TW |
dc.contributor.department |
National Chiao Tung University | en_US |
dc.date.accessioned |
2018-08-21T05:54:02Z | |
dc.date.available |
2018-08-21T05:54:02Z | |
dc.date.issued |
2017-05-01 | en_US |
dc.description.abstract |
This paper presents the development of an oscillator and a detector based on InP HBT technology operating near 300 GHz, and their application to terahertz reflection-mode imaging. The fabricated fundamental-mode common-base (CB) cross-coupled oscillator exhibits a peak output power of 5.3 dBm at 305.8 GHz, and the CB direct detector shows a responsivity higher than 40 kV/W and noise equivalent power lower than 35 pW/root Hz for a frequency range of 270-345 GHz. The imaging system employing the fabricated circuits as the signal source and detector was characterized for the resolution and dynamic range, and then, successfully applied for imaging various biological samples. The results show that low-power terahertz reflection-mode imaging based on solid-state electronic sources and detectors based on a commercial semiconductor technology is promising for various biomedical imaging applications. | en_US |
dc.identifier.doi |
10.1109/TTHZ.2017.2673549 | en_US |
dc.identifier.issn |
2156-342X | en_US |
dc.identifier.journal |
IEEE TRANSACTIONS ON TERAHERTZ SCIENCE AND TECHNOLOGY | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1109/TTHZ.2017.2673549 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/145493 | |
dc.identifier.wosnumber |
WOS:000401094100006 | en_US |
dc.language.iso |
en_US | en_US |
dc.subject |
Detectors | en_US |
dc.subject |
heterojunction bipolar transistors (HBTs) | en_US |
dc.subject |
imaging | en_US |
dc.subject |
oscillators | en_US |
dc.subject |
signal generators | en_US |
dc.subject |
terahertz | en_US |
dc.title |
Terahertz Reflection-Mode Biological Imaging Based on InP HBT Source and Detector | en_US |
dc.type |
Article | en_US |
檔案
本條目沒有附加檔案。
所屬典藏: 期刊論文
引用此條目
Yun, J., Oh, S. J., Song, K., Yoon, D., Son, H. Y., Choi, Y., Huh, Y.-M., & Rieh, J.-S. (2017). Terahertz Reflection-Mode Biological Imaging Based on InP HBT Source and Detector. IEEE TRANSACTIONS ON TERAHERTZ SCIENCE AND TECHNOLOGY, 7, 274–283. https://doi.org/10.1109/TTHZ.2017.2673549
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/145493