Improving the Accuracy of the Leakage Power Estimation of Embedded CPUs
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
1236 | en_US |
dc.citation.spage |
1233 | en_US |
dc.contributor.author |
Chin, Ting-Wu | en_US |
dc.contributor.author |
Tsao, Shiao-Li | en_US |
dc.contributor.author |
Hung, Kuo-Wei | en_US |
dc.contributor.author |
Huang, Pei-Shu | en_US |
dc.contributor.department |
資訊工程學系 | zh_TW |
dc.contributor.department |
Department of Computer Science | en_US |
dc.date.accessioned |
2018-08-21T05:56:48Z | |
dc.date.available |
2018-08-21T05:56:48Z | |
dc.date.issued |
2017-01-01 | en_US |
dc.description.abstract |
Previous studies have used on-chip thermal sensors (diodes) to estimate the leakage power of a CPU. However, an embedded CPU equips only a few thermal sensors and may suffer from considerable spatial temperature variances across the CPU core, and leakage power estimation based on insufficient temperature information introduces errors. According to our experiments, the conventional leakage power models may have up to 22.9% estimation error for a 70-nm embedded CPU. In this study, we first evaluated the accuracy of leakage power estimates based on thermal sensors on different locations of a CPU and suggested locations that can reduce the error to 0.9%. Then, we proposed temperature-referred and counter-tracked estimation (TRACE) that relies on temperature sensors and hardware activity counters to estimate leakage power. The simulation results demonstrated that employing TRACE could reduce the error to 3.4%. Experiments were also conducted on a real platform to verify our findings. | en_US |
dc.identifier.issn |
1530-1591 | en_US |
dc.identifier.journal |
PROCEEDINGS OF THE 2017 DESIGN, AUTOMATION & TEST IN EUROPE CONFERENCE & EXHIBITION (DATE) | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/146676 | |
dc.identifier.wosnumber |
WOS:000404171500229 | en_US |
dc.language.iso |
en_US | en_US |
dc.subject |
leakage power | en_US |
dc.subject |
modeling | en_US |
dc.subject |
thermal sensor | en_US |
dc.title |
Improving the Accuracy of the Leakage Power Estimation of Embedded CPUs | en_US |
dc.type |
Proceedings Paper | en_US |
檔案
本條目沒有附加檔案。
所屬典藏: 會議論文
引用此條目
Chin, T.-W., Tsao, S.-L., Hung, K.-W., & Huang, P.-S. (2017). Improving the Accuracy of the Leakage Power Estimation of Embedded CPUs. PROCEEDINGS OF THE 2017 DESIGN, AUTOMATION & TEST IN EUROPE CONFERENCE & EXHIBITION (DATE), 1233–1236. https://ir.lib.nycu.edu.tw/handle/11536/146676
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/146676