High Ranging Accuracy and Wide Detection Range Interferometry Based on Frequency-Sweeping Technique With Vital Sign Sensing Function
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
4251 | en_US |
dc.citation.spage |
4242 | en_US |
dc.citation.volume |
66 | en_US |
dc.citation.woscount |
0 | en_US |
dc.contributor.author |
Liu, Tsung-Hsin | en_US |
dc.contributor.author |
Hsu, Miao-Lin | en_US |
dc.contributor.author |
Tsai, Zuo-Min | en_US |
dc.contributor.department |
交大名義發表 | zh_TW |
dc.contributor.department |
National Chiao Tung University | en_US |
dc.date.accessioned |
2019-04-02T05:57:52Z | |
dc.date.available |
2019-04-02T05:57:52Z | |
dc.date.issued |
2018-09-01 | en_US |
dc.description.abstract |
In this paper, an interferometry-based frequency-sweeping technique has been developed and demonstrated. With this approach, the distance ambiguity problem in the traditional interferometer is solved. The relationship involving the used carrier number, noise and standing wave effects, the root-mean-square error, and the maximum unambiguous range are illustrated and discussed. The detection error caused by the noise and the standing wave effects is effectively reduced by properly increasing the used carrier number within the same bandwidth. The experiment indicates that the maximum detection error of a metal reflector detection is below 23 mu m at a distance of S m. In addition, the vital sign sensing experiments are demonstrated. With this approach, the motion amplitude and frequency of the respiration and the heartbeats are constructed. | en_US |
dc.identifier.doi |
10.1109/TMTT.2018.2854177 | en_US |
dc.identifier.issn |
0018-9480 | en_US |
dc.identifier.journal |
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1109/TMTT.2018.2854177 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/148111 | |
dc.identifier.wosnumber |
WOS:000444009500035 | en_US |
dc.language.iso |
en_US | en_US |
dc.subject |
Distance measurement | en_US |
dc.subject |
frequency sweeping | en_US |
dc.subject |
interferometer | en_US |
dc.subject |
standing wave | en_US |
dc.subject |
vital sign detection | en_US |
dc.title |
High Ranging Accuracy and Wide Detection Range Interferometry Based on Frequency-Sweeping Technique With Vital Sign Sensing Function | en_US |
dc.type |
Article | en_US |
檔案
本條目沒有附加檔案。
所屬典藏: 期刊論文
引用此條目
Liu, T.-H., Hsu, M.-L., & Tsai, Z.-M. (2018). High Ranging Accuracy and Wide Detection Range Interferometry Based on Frequency-Sweeping Technique With Vital Sign Sensing Function. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 66, 4242–4251. https://doi.org/10.1109/TMTT.2018.2854177
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/148111