Functionalized N-doped graphene quantum dots for electrochemical determination of cholesterol through host-guest inclusion
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.volume |
185 | en_US |
dc.citation.woscount |
1 | en_US |
dc.contributor.author |
Ganganboina, Akhilesh Babu | en_US |
dc.contributor.author |
Doong, Ruey-an | en_US |
dc.contributor.department |
環境工程研究所 | zh_TW |
dc.contributor.department |
Institute of Environmental Engineering | en_US |
dc.date.accessioned |
2019-04-02T05:59:51Z | |
dc.date.available |
2019-04-02T05:59:51Z | |
dc.date.issued |
2018-11-01 | en_US |
dc.description.abstract |
Functionalized nitrogen-doped graphene quantum dots (N-GQD) with mean particle size of 8.50.5nm were covalently linked to -cyclodextrin (-CD) to form a -CD@N-GQD nanoprobe. The probe is shown to enable voltammetric determination of cholesterol via selective host-guest recognition and by using ferrocene (FC) as the redox indicator.FC is first included in-cyclodextrin. Cholesterol has ahigher affinity for -CD (in comparison to FC). It forms a strong inclusion complex with -CD and can replace FC from its cavities. The quantity of released FC is proportional to the concentration of cholesterol. The differential pulse voltammetric signal for FC (with a peak at typically 0.22V vs Ag/AgCl) increases linearly in the 0.5-100M cholesterol concentration range, with a limit of detection as low as 80nM. The assay is found to be highly selective over 15 potentially interfering species. The method was successfully applied to the detection of cholesterol in spiked serum samples which gave recoveries between 96 and 101%. The probe can be stored for at least 28days after which the activity still is 87%. | en_US |
dc.identifier.doi |
10.1007/s00604-018-3063-4 | en_US |
dc.identifier.issn |
0026-3672 | en_US |
dc.identifier.journal |
MICROCHIMICA ACTA | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1007/s00604-018-3063-4 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/148392 | |
dc.identifier.wosnumber |
WOS:000448847500002 | en_US |
dc.language.iso |
en_US | en_US |
dc.subject |
Electrochemical assay | en_US |
dc.subject |
Nanoprobe | en_US |
dc.subject |
Ferrocene | en_US |
dc.subject |
Covalent linkage | en_US |
dc.subject |
Human serum sample | en_US |
dc.subject |
Differential pulse voltammetry (DPV) | en_US |
dc.title |
Functionalized N-doped graphene quantum dots for electrochemical determination of cholesterol through host-guest inclusion | en_US |
dc.type |
Article | en_US |
檔案
本條目沒有附加檔案。
所屬典藏: 期刊論文
引用此條目
Ganganboina, A. B., & Doong, R.-A. (2018). Functionalized N-doped graphene quantum dots for electrochemical determination of cholesterol through host-guest inclusion. MICROCHIMICA ACTA, 185. https://doi.org/10.1007/s00604-018-3063-4
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/148392