Co-placement optimization in sensor-reusable cyber-physical digital microfluidic biochips
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
196 | en_US |
dc.citation.spage |
185 | en_US |
dc.citation.volume |
83 | en_US |
dc.citation.woscount |
0 | en_US |
dc.contributor.author |
Li, Jian-De | en_US |
dc.contributor.author |
Kuo, Chun-Hao | en_US |
dc.contributor.author |
Lu, Guan-Ruei | en_US |
dc.contributor.author |
Wang, Sying-Jyan | en_US |
dc.contributor.author |
Li, Katherine Shu-Min | en_US |
dc.contributor.author |
Ho, Tsung-Yi | en_US |
dc.contributor.author |
Chen, Hung-Ming | en_US |
dc.contributor.author |
Hu, Shiyan | en_US |
dc.contributor.department |
電子工程學系及電子研究所 | zh_TW |
dc.contributor.department |
Department of Electronics Engineering and Institute of Electronics | en_US |
dc.date.accessioned |
2019-04-02T06:00:15Z | |
dc.date.available |
2019-04-02T06:00:15Z | |
dc.date.issued |
2019-01-01 | en_US |
dc.description.abstract |
Digital microfluidic biochips (DMFBs) facilitate modern healthcare applications. One of the most important applications is point-of-care (POC) clinical diagnosis which is directly related to human health. However, biochemical experiments are usually error-prone, which makes monitoring intermediate results during bioassay execution be required to ensure the correctness of POC clinical diagnosis. To tackle this problem, cyber-physical digital microfluidic biochips with integrated sensors have been proposed and have attracted attention recently. In order to fully utilize the sensors for detection, the reusability of sensors should be taken into consideration during the module placement stage of cyber-physical DMFBs synthesis flow. Moreover, excessive actuation of electrodes may cause reliability degradation and this issuse should also be taken care of during module placement stage. In order to deal with the aforementioned problems, this paper presents the first co-optimization method for both module and sensor placement. Experimental results show that the proposed method can effectively minimize bioassay completion time while meeting all constraints from sensors and electrodes. | en_US |
dc.identifier.doi |
10.1016/j.mejo.2018.08.005 | en_US |
dc.identifier.issn |
0026-2692 | en_US |
dc.identifier.journal |
MICROELECTRONICS JOURNAL | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1016/j.mejo.2018.08.005 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/148768 | |
dc.identifier.wosnumber |
WOS:000456730500021 | en_US |
dc.language.iso |
en_US | en_US |
dc.subject |
Digital microfluidic biochips | en_US |
dc.subject |
Cyber-physical sys-tem | en_US |
dc.subject |
Sensor | en_US |
dc.subject |
Placement | en_US |
dc.subject |
Reliability | en_US |
dc.title |
Co-placement optimization in sensor-reusable cyber-physical digital microfluidic biochips | en_US |
dc.type |
Article | en_US |
檔案
本條目沒有附加檔案。
所屬典藏: 期刊論文
引用此條目
Li, J.-D., Kuo, C.-H., Lu, G.-R., Wang, S.-J., Li, K. S.-M., Ho, T.-Y., Chen, H.-M., & Hu, S. (2019). Co-placement optimization in sensor-reusable cyber-physical digital microfluidic biochips. MICROELECTRONICS JOURNAL, 83, 185–196. https://doi.org/10.1016/j.mejo.2018.08.005
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/148768