A pyrophosphatase biosensor with photocurrent analysis
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
163 | en_US |
dc.citation.spage |
159 | en_US |
dc.citation.volume |
284 | en_US |
dc.citation.woscount |
0 | en_US |
dc.contributor.author |
Lee, Cheng-Yu | en_US |
dc.contributor.author |
Liao, Chi-Hsiang | en_US |
dc.contributor.author |
Tso, Jen-Te | en_US |
dc.contributor.author |
Hsieh, You-Zung | en_US |
dc.contributor.department |
交大名義發表 | zh_TW |
dc.contributor.department |
應用化學系 | zh_TW |
dc.contributor.department |
National Chiao Tung University | en_US |
dc.contributor.department |
Department of Applied Chemistry | en_US |
dc.date.accessioned |
2019-04-02T05:58:21Z | |
dc.date.available |
2019-04-02T05:58:21Z | |
dc.date.issued |
2019-04-01 | en_US |
dc.description.abstract |
A light-induced photochemical biosensor was developed for the analysis of inorganic pyrophosphatase (PPase). PPase hydrolyzes pyrophosphate (PPi) into two independent o-phosphate ions. Two PPi units can chelate a copper ion (Cu2+), forming a PPi-Cu2+-PPi complex and preventing the Cu2+ triggers other reactions. A transparent indium tin oxide (ITO) electrode was coated with a layer of CdS quantum dots (QDs), and then 3,4-diaminobenzoic acid (DBA) was deposited as the anchor. A solution of the PPi-Cu2+-PPi complex and o-phenylenediamine (OPD) was mixed with the analytical sample and then a drop of the mixture was placed on the modified ITO electrode. In the absence of PPase, no reaction occurred between OPD and DBA. A photocurrent was obtained upon excitation of the CdS QDs under light. In the presence of PPase, Cu2+ was released from the complex, triggering the reaction of OPD with DBA on the electrode surface, thereby shielding the CdS QDs from excitation by the light. The observed photocurrent decreased. The difference in the two measured photocurrents corresponded to the activity of PPase. This photochemical biosensor had excellent sensitivity for PPase in the range from 0.8 to 5000 mU, with a limit of detection of 0.41 mU. | en_US |
dc.identifier.doi |
10.1016/j.snb.2018.12.123 | en_US |
dc.identifier.issn |
0925-4005 | en_US |
dc.identifier.journal |
SENSORS AND ACTUATORS B-CHEMICAL | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1016/j.snb.2018.12.123 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/148955 | |
dc.identifier.wosnumber |
WOS:000460404100021 | en_US |
dc.language.iso |
en_US | en_US |
dc.subject |
Biosensor | en_US |
dc.subject |
PPase | en_US |
dc.subject |
Photocurrent | en_US |
dc.subject |
Quantum dots | en_US |
dc.subject |
o-Phenylenediamine | en_US |
dc.title |
A pyrophosphatase biosensor with photocurrent analysis | en_US |
dc.type |
Article | en_US |
檔案
本條目沒有附加檔案。
所屬典藏: 期刊論文
引用此條目
Lee, C.-Y., Liao, C.-H., Tso, J.-T., & Hsieh, Y.-Z. (2019). A pyrophosphatase biosensor with photocurrent analysis. SENSORS AND ACTUATORS B-CHEMICAL, 284, 159–163. https://doi.org/10.1016/j.snb.2018.12.123
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/148955