Integrated semiconductor optoelectronic devices for real-time and indicator-free detection of aqueous nitric oxide
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
0 | en_US |
dc.citation.spage |
0 | en_US |
dc.citation.volume |
8118 | en_US |
dc.citation.woscount |
0 | en_US |
dc.contributor.author |
Wang, Shin-Ping | en_US |
dc.contributor.author |
Cheng, Yi-Kai | en_US |
dc.contributor.author |
Chao, Yu-Chiang | en_US |
dc.contributor.author |
Zan, Hsiao-Wen | en_US |
dc.contributor.author |
Chang, Gao-Fong | en_US |
dc.contributor.author |
Meng, Hsin-Fei | en_US |
dc.contributor.author |
Hung, Chen-Hsiung | en_US |
dc.contributor.author |
Chen, Wen-Chang | en_US |
dc.contributor.department |
物理研究所 | zh_TW |
dc.contributor.department |
光電工程學系 | zh_TW |
dc.contributor.department |
Institute of Physics | en_US |
dc.contributor.department |
Department of Photonics | en_US |
dc.date.accessioned |
2019-04-03T06:47:36Z | |
dc.date.available |
2019-04-03T06:47:36Z | |
dc.date.issued |
2011-01-01 | en_US |
dc.description.abstract |
Sensing films specific to nitric oxide and zinc were fabricated by embedding respectively indicator 1,2-diaminoanthraquinone (DAQ) and 11,16-Bis(phenyl)-6,6,21,21-tetramethyl-m-benzi-6,21-porphodimethene (BPDM-H) in hydrogel host poly(2-hydroxyethyl methacrylate). The sensing film contains DAQ, which responses to nitric oxide, shows stability in acid environment. The sensing film contains BPDM-H responses to zinc. The electrospinning technique was also utilized to fabricate the fibrous film. | en_US |
dc.identifier.doi |
10.1117/12.893012 | en_US |
dc.identifier.isbn |
978-0-81948-728-5 | en_US |
dc.identifier.issn |
0277-786X | en_US |
dc.identifier.journal |
ORGANIC SEMICONDUCTORS IN SENSORS AND BIOELECTRONICS IV | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1117/12.893012 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/150545 | |
dc.identifier.wosnumber |
WOS:000297625300003 | en_US |
dc.language.iso |
en_US | en_US |
dc.subject |
probe | en_US |
dc.subject |
organic electronic devices | en_US |
dc.title |
Integrated semiconductor optoelectronic devices for real-time and indicator-free detection of aqueous nitric oxide | en_US |
dc.type |
Proceedings Paper | en_US |
檔案
- ed316b92b1e4e0b841bad2adca0e9e66.pdf (1.74 MB, Adobe PDF)
所屬典藏: 會議論文
引用此條目
Wang, S.-P., Cheng, Y.-K., Chao, Y.-C., Zan, H.-W., Chang, G.-F., Meng, H.-F., Hung, C.-H., & Chen, W.-C. (2011). Integrated semiconductor optoelectronic devices for real-time and indicator-free detection of aqueous nitric oxide. ORGANIC SEMICONDUCTORS IN SENSORS AND BIOELECTRONICS IV, 8118, 0. https://doi.org/10.1117/12.893012
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享