A low-cost, portable and easy-operated salivary urea sensor for point-of-care application
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
359 | en_US |
dc.citation.spage |
352 | en_US |
dc.citation.volume |
132 | en_US |
dc.citation.woscount |
0 | en_US |
dc.contributor.author |
Wang, Kuan-Hsun | en_US |
dc.contributor.author |
Hsieh, Ju-Chun | en_US |
dc.contributor.author |
Chen, Chang-Chiang | en_US |
dc.contributor.author |
Zan, Hsiao-Wen | en_US |
dc.contributor.author |
Meng, Hsin-Fei | en_US |
dc.contributor.author |
Kuo, Sheng-Yu | en_US |
dc.contributor.author |
Minh Tram Ngoc Nguyen | en_US |
dc.contributor.department |
交大名義發表 | zh_TW |
dc.contributor.department |
分子醫學與生物工程研究所 | zh_TW |
dc.contributor.department |
物理研究所 | zh_TW |
dc.contributor.department |
光電工程學系 | zh_TW |
dc.contributor.department |
National Chiao Tung University | en_US |
dc.contributor.department |
Institute of Molecular Medicine and Bioengineering | en_US |
dc.contributor.department |
Institute of Physics | en_US |
dc.contributor.department |
Department of Photonics | en_US |
dc.date.accessioned |
2019-05-02T00:25:48Z | |
dc.date.available |
2019-05-02T00:25:48Z | |
dc.date.issued |
2019-05-01 | en_US |
dc.description.abstract |
Salivary urea was reported to be a useful biomarker to reflect the blood urea nitrogen in chronic kidney disease patients. However, as a new biomarker, enormous clinical trials are required to define the intended-use and to verify the specification. In this report, we demonstrated a low-cost easy-operated real-time sensing system (optical fiber-urea-sensing, OFUS, system) to detect salivary urea. We aim to make the system easily reproduced by the community to stimulate abundant clinical tests worldwide. The OFUS system is composed of a simple three-dimensional printed tank to link with two optical fibers, one connecting with a commercial light-emitting diode to deliver the input light signal, the other connecting with a commercial cadmium sulfide photo-conductive cell to detect the sensing signal. To allow on-site detection without any sample pretreatment, only 1 mu l saliva is needed to be mixed with 10 mu l urease solution and 90 mu l pH indicator solution in the reaction tank and the detection time is only 20 s. A stable and reproducible calibration curve can be easily built with a detection range as 24-300 mg/dL. The OFUS system successfully detected saliva with added synthetic urea and samples from chronic kidney disease patients. A good agreement between the OFUS system and the commercial kit was obtained. A good correlation between salivary urea and the blood urea nitrogen was also confirmed. | en_US |
dc.identifier.doi |
10.1016/j.bios.2019.03.007 | en_US |
dc.identifier.issn |
0956-5663 | en_US |
dc.identifier.journal |
BIOSENSORS & BIOELECTRONICS | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1016/j.bios.2019.03.007 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/151576 | |
dc.identifier.wosnumber |
WOS:000464296300041 | en_US |
dc.language.iso |
en_US | en_US |
dc.subject |
Non-invasive | en_US |
dc.subject |
Salivary urea | en_US |
dc.subject |
Real-time | en_US |
dc.subject |
Optical fiber | en_US |
dc.subject |
Point-of-care | en_US |
dc.title |
A low-cost, portable and easy-operated salivary urea sensor for point-of-care application | en_US |
dc.type |
Article | en_US |
檔案
本條目沒有附加檔案。
所屬典藏: 期刊論文
引用此條目
Wang, K.-H., Hsieh, J.-C., Chen, C.-C., Zan, H.-W., Meng, H.-F., Kuo, S.-Y., & Minh Tram Ngoc Nguyen (2019). A low-cost, portable and easy-operated salivary urea sensor for point-of-care application. BIOSENSORS & BIOELECTRONICS, 132, 352–359. https://doi.org/10.1016/j.bios.2019.03.007
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/151576