System accuracy assessments with a blood glucose meter with combined glucose and ss-hydroxybutyrate measurement capabilities
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
0 | en_US |
dc.citation.spage |
0 | en_US |
dc.citation.woscount |
0 | en_US |
dc.contributor.author |
Weissenbacher, Sylvia | en_US |
dc.contributor.author |
Yang, Chen-Yu | en_US |
dc.contributor.author |
Kuan, Tang-Chin | en_US |
dc.contributor.author |
Demircik, Filiz | en_US |
dc.contributor.author |
Hanna, Mina | en_US |
dc.contributor.author |
Pfuetzner, Andreas | en_US |
dc.contributor.department |
交大名義發表 | zh_TW |
dc.contributor.department |
National Chiao Tung University | en_US |
dc.date.accessioned |
2019-10-05T00:08:48Z | |
dc.date.available |
2019-10-05T00:08:48Z | |
dc.date.issued |
1970-01-01 | en_US |
dc.description.abstract |
Background: We evaluated the Wellion Galileo GLU/KET blood and ketone (ss-Hydroxybutyrate, ss-OHB) meter to demonstrate that it meets ISO15107:2015 regulatory approval criteria. Research Design and Methods: A total of 100 subjects (52 female, age: 30 to 84 years, diabetes: 10 type 1/90 type 2) with blood glucose levels distributed over the entire measurement range as required by the ISO15197 protocol were tested (double determinations with 3 strip lots and two devices). A similar test protocol was followed to test ss-OHB strip performance (reference devices: YSI 2300plus for glucose and STANBIO ss-HOB LiquiColor TestKit for ss-OHB). Precision was tested for glucose with 3 blood glucose concentrations (ss-OHB: 2 control solutions). Results: All glucose test-strip lots met the strict ISO acceptance criteria. Mean absolute relative difference (MARD) was 4.9% and all data pairs were in zone A of the consensus error grid. The ss-OHB test-strips also met the pre-defined acceptance criteria. Within-run and between-run precision was calculated to be 2.3% and 0.7% for the glucose strips (3.7%/0.8% for the ketone strips). Conclusions: When tested according to the ISO15197:2015 guideline, the device showed very accurate measurement performance for glucose and ss-OHB testing and fully met regulatory accuracy approval criteria. | en_US |
dc.identifier.doi |
10.1080/14737159.2019.1662300 | en_US |
dc.identifier.issn |
1473-7159 | en_US |
dc.identifier.journal |
EXPERT REVIEW OF MOLECULAR DIAGNOSTICS | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1080/14737159.2019.1662300 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/152884 | |
dc.identifier.wosnumber |
WOS:000484998800001 | en_US |
dc.language.iso |
en_US | en_US |
dc.subject |
Blood glucose meter | en_US |
dc.subject |
accuracy | en_US |
dc.subject |
precision | en_US |
dc.subject |
ss-hydroxybutyrate | en_US |
dc.subject |
ss-OHB | en_US |
dc.title |
System accuracy assessments with a blood glucose meter with combined glucose and ss-hydroxybutyrate measurement capabilities | en_US |
dc.type |
Article | en_US |
檔案
本條目沒有附加檔案。
所屬典藏: 期刊論文
引用此條目
Weissenbacher, S., Yang, C.-Y., Kuan, T.-C., Demircik, F., Hanna, M., & Pfuetzner, A. (1970). System accuracy assessments with a blood glucose meter with combined glucose and ss-hydroxybutyrate measurement capabilities. EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 0. https://doi.org/10.1080/14737159.2019.1662300
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/152884