Fire suppression performance of water mist under diverse desmoking and ventilation conditions
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
242 | en_US |
dc.citation.spage |
230 | en_US |
dc.citation.volume |
133 | en_US |
dc.citation.woscount |
0 | en_US |
dc.contributor.author |
Liu, Wei-Yi | en_US |
dc.contributor.author |
Chen, Chiun-Hsun | en_US |
dc.contributor.author |
Shu, Yi-Liang | en_US |
dc.contributor.author |
Chen, Wei-Ting | en_US |
dc.contributor.author |
Shu, Chi-Min | en_US |
dc.contributor.department |
機械工程學系 | zh_TW |
dc.contributor.department |
Department of Mechanical Engineering | en_US |
dc.date.accessioned |
2020-02-02T23:54:28Z | |
dc.date.available |
2020-02-02T23:54:28Z | |
dc.date.issued |
2020-01-01 | en_US |
dc.description.abstract |
This paper described full-scale tests of water mist fire suppression system under forced desmoking conditions. Pool fire was effectively suppressed in 25.0 and 37.0 s for 1,500.0 (test 1) and 3,000.0 (test 2) mL of oil with no ventilation, respectively. Moreover, under ventilation rates of 50.0 and 75.0 m(3)/min, the suppression time were lengthened to 54.0 s (test 1) and 202.0 s (test 2), and 102.0 s (test 1) and 222.0 s (test 2), correspondingly. However, the smoke exhaust had a strong effect on the water mist to result in fire could not extinguish, when the ventilation rate increased to 120.0 m(3)/min. The temperature distribution during the early period in the scenario of no ventilation has a higher magnitude than those scenarios of 50.0, 75.0, and 120.0 m(3)/min, because combustion proceeds smoothly to result in temperature increased rapidly at no ventilation. Furthermore, similar results presented in smoke concentration distribution at four scenarios (0, 50.0, 75.0, and 120.0 m(3)/min), and combustion occurred steadily at no ventilation to result in more smoke during the early period. This study employed a computer modeling to verify water mist system in a compartment space and determine how the water mist system could be optimized. (C) 2019 Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved. | en_US |
dc.identifier.doi |
10.1016/j.psep.2019.10.019 | en_US |
dc.identifier.issn |
0957-5820 | en_US |
dc.identifier.journal |
PROCESS SAFETY AND ENVIRONMENTAL PROTECTION | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1016/j.psep.2019.10.019 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/153504 | |
dc.identifier.wosnumber |
WOS:000506408700021 | en_US |
dc.language.iso |
en_US | en_US |
dc.subject |
Water mist fire suppression system | en_US |
dc.subject |
Pool fire | en_US |
dc.subject |
Forced desmoking conditions | en_US |
dc.subject |
Suppression time | en_US |
dc.subject |
Compartment space | en_US |
dc.title |
Fire suppression performance of water mist under diverse desmoking and ventilation conditions | en_US |
dc.type |
Article | en_US |