Titanium dioxide-mediated resistive nanobiosensor for E. coli O157:H7
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
0 | en_US |
dc.citation.issue |
4 | en_US |
dc.citation.spage |
0 | en_US |
dc.citation.volume |
187 | en_US |
dc.citation.woscount |
0 | en_US |
dc.contributor.author |
Nadzirah, Sh. | en_US |
dc.contributor.author |
Hashim, U. | en_US |
dc.contributor.author |
Gopinath, Subash C. B. | en_US |
dc.contributor.author |
Parmin, N. A. | en_US |
dc.contributor.author |
Hamzah, Azrul Azlan | en_US |
dc.contributor.author |
Yu, Hung Wei | en_US |
dc.contributor.author |
Dee, Chang Fu | en_US |
dc.contributor.department |
材料科學與工程學系 | zh_TW |
dc.contributor.department |
Department of Materials Science and Engineering | en_US |
dc.date.accessioned |
2020-05-05T00:02:24Z | |
dc.date.available |
2020-05-05T00:02:24Z | |
dc.date.issued |
2020-03-17 | en_US |
dc.description.abstract |
A titanium dioxide nanoparticle (TiO2 NP)-mediated resistive biosensor is described for the determination of DNA fragments of Escherichia coli O157:H7 (E. coli O157:H7). The sol-gel method was used to synthesize the TiO2 NP, and microlithography was applied to fabricate the interdigitated sensor electrodes. Conventional E. coli DNA detections are facing difficulties in long-preparation-and-detection-time (more than 3 days). Hence, electronic biosensor was introduced by measuring the current-voltage (I-V) DNA probe without amplification of DNA fragments. The detection scheme is based on the interaction between the electron flow on the sensor and the introduction of negative charges from DNA probe and target DNA. The biosensor has a sensitivity of 1.67 x 10(13) omega/M and a wide analytical range. The limit detection is down to 1 x 10(-11) M of DNA. The sensor possesses outstanding repeatability and reproducibility and is cabable to detect DNA within 15 min in a minute-volume sample (1 mu L). | en_US |
dc.identifier.doi |
10.1007/s00604-020-4214-y | en_US |
dc.identifier.issn |
0026-3672 | en_US |
dc.identifier.journal |
MICROCHIMICA ACTA | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1007/s00604-020-4214-y | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/154205 | |
dc.identifier.wosnumber |
WOS:000520204900001 | en_US |
dc.language.iso |
en_US | en_US |
dc.subject |
Titanium dioxide nanoparticles | en_US |
dc.subject |
Poultry sample detection | en_US |
dc.subject |
Interdigitated electrode | en_US |
dc.subject |
Microlithography | en_US |
dc.subject |
Electrical detection | en_US |
dc.title |
Titanium dioxide-mediated resistive nanobiosensor for E. coli O157:H7 | en_US |
dc.type |
Article | en_US |
檔案
本條目沒有附加檔案。
所屬典藏: 期刊論文
引用此條目
Nadzirah, S., Hashim, U., Gopinath, S. C. B., Parmin, N. A., Hamzah, A. A., Yu, H. W., & Dee, C. F. (2020). Titanium dioxide-mediated resistive nanobiosensor for E. coli O157:H7. MICROCHIMICA ACTA, 187(4), 0. https://doi.org/10.1007/s00604-020-4214-y
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享