Label-Free Impedimetric Immunosensors Modulated by Protein A/Bovine Serum Albumin Layer for Ultrasensitive Detection of Salbutamol
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
0 | en_US |
dc.citation.issue |
3 | en_US |
dc.citation.spage |
0 | en_US |
dc.citation.volume |
20 | en_US |
dc.citation.woscount |
0 | en_US |
dc.contributor.author |
Lin, Chia-Hung | en_US |
dc.contributor.author |
Lin, Ming-Jie | en_US |
dc.contributor.author |
Huang, Jie-De | en_US |
dc.contributor.author |
Chuang, Yu-Sheng | en_US |
dc.contributor.author |
Kuo, Yu-Fen | en_US |
dc.contributor.author |
Chen, Jung-Chih | en_US |
dc.contributor.author |
Wu, Ching-Chou | en_US |
dc.contributor.department |
分子醫學與生物工程研究所 | zh_TW |
dc.contributor.department |
Institute of Molecular Medicine and Bioengineering | en_US |
dc.date.accessioned |
2020-05-05T00:02:25Z | |
dc.date.available |
2020-05-05T00:02:25Z | |
dc.date.issued |
2020-02-01 | en_US |
dc.description.abstract |
The sensing properties of immunosensors are determined not only by the amount of immobilized antibodies but also by the number of effective antigen-binding sites of the immobilized antibody. Protein A (PA) exhibits a high degree of affinity with the Fc part of IgG antibody to feasibly produce oriented antibody immobilization. This work proposes a simple method to control the PA surface density on gold nanostructure (AuNS)-deposited screen-printed carbon electrodes (SPCEs) by mixing concentration-varied PA and bovine serum albumin (BSA), and to explore the effect of PA density on the affinity attachment of anti-salbutamol (SAL) antibodies by electrochemical impedance spectroscopy. A concentration of 100 mu g/mL PA and 100 mu g/mL BSA can obtain a saturated coverage on the 3-mercaptoproponic acid (MPA)/AuNS/SPCEs and exhibit a 50% PA density to adsorb the amount of anti-SAL, more than other concentration-varied PA/BSA-modified electrodes. Compared with the randomly immobilized anti-SAL/MPA/AuNS/SPCEs and the anti-SAL/PA(100 mu g/mL):BSA(0 mu g/mL)/MPA/AuNS/SPCE, the anti-SAL/PA(100 mu g/mL): BSA(100 mu g/mL)/MPA/AuNS/SPCE-based immunosensors have better sensing properties for SAL detection, with an extremely low detection limit of 0.2 fg/mL and high reproducibility (<2.5% relative standard deviation). The mixture of PA(100 mu g/mL):BSA(100 mu g/mL) for the modification of AuNS/SPCEs has great promise for forming an optimal protein layer for the oriented adsorption of IgG antibodies to construct ultrasensitive SAL immunosensors. | en_US |
dc.identifier.doi |
10.3390/s20030771 | en_US |
dc.identifier.journal |
SENSORS | en_US |
dc.identifier.uri |
http://dx.doi.org/10.3390/s20030771 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/154233 | |
dc.identifier.wosnumber |
WOS:000517786200195 | en_US |
dc.language.iso |
en_US | en_US |
dc.subject |
protein A | en_US |
dc.subject |
surface density | en_US |
dc.subject |
oriented immobilization | en_US |
dc.subject |
electrochemical impedance spectroscopy | en_US |
dc.subject |
immunosensor | en_US |
dc.title |
Label-Free Impedimetric Immunosensors Modulated by Protein A/Bovine Serum Albumin Layer for Ultrasensitive Detection of Salbutamol | en_US |
dc.type |
Article | en_US |
檔案
本條目沒有附加檔案。
所屬典藏: 期刊論文
引用此條目
Lin, C.-H., Lin, M.-J., Huang, J.-D., Chuang, Y.-S., Kuo, Y.-F., Chen, J.-C., & Wu, C.-C. (2020). Label-Free Impedimetric Immunosensors Modulated by Protein A/Bovine Serum Albumin Layer for Ultrasensitive Detection of Salbutamol. SENSORS, 20(3), 0. https://doi.org/10.3390/s20030771
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/154233