A 0.3V 10b 3MS/s SAR ADC With Comparator Calibration and Kickback Noise Reduction for Biomedical Applications
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
569 | en_US |
dc.citation.issue |
3 | en_US |
dc.citation.spage |
558 | en_US |
dc.citation.volume |
14 | en_US |
dc.citation.woscount |
0 | en_US |
dc.contributor.author |
Wang, Shih-Hsing | en_US |
dc.contributor.author |
Hung, Chung-Chih | en_US |
dc.contributor.department |
電機資訊學士班 | zh_TW |
dc.contributor.department |
Undergraduate Honors Program of Electrical Engineering and Computer Science | en_US |
dc.date.accessioned |
2020-07-01T05:22:04Z | |
dc.date.available |
2020-07-01T05:22:04Z | |
dc.date.issued |
2020-06-01 | en_US |
dc.description.abstract |
This paper presents a 10-bit successive approximation analog-to-digital converter (ADC) that operates at an ultralow voltage of 0.3 V and can be applied to biomedical implants. The study proposes several techniques to improve the ADC performance. A pipeline comparator was utilized to maintain the advantages of dynamic comparators and reduce the kickback noise. Weight biasing calibration was used to correct the offset voltage without degrading the operating speed of the comparator. The incorporation of a unity-gain buffer improved the bootstrap switch leakage problem during the hold period and reduced the effect of parasitic capacitances on the digital-to-analog converter. The chip was fabricated using 90-nm CMOS technology. The data measured at a supply voltage of 0.3 V and sampling rate of 3 MSps for differential nonlinearity and integral nonlinearity were +0.83/-0.54 and +0.84/-0.89, respectively, and the signal-to-noise plus distortion ratio and effective number of bits were 56.42 dB and 9.08 b, respectively. The measured total power consumption was 6.6 mu W at a figure of merit of 4.065 fJ/conv.-step. | en_US |
dc.identifier.doi |
10.1109/TBCAS.2020.2982912 | en_US |
dc.identifier.issn |
1932-4545 | en_US |
dc.identifier.journal |
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1109/TBCAS.2020.2982912 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/154497 | |
dc.identifier.wosnumber |
WOS:000538042700015 | en_US |
dc.language.iso |
en_US | en_US |
dc.subject |
Switches | en_US |
dc.subject |
Calibration | en_US |
dc.subject |
Power demand | en_US |
dc.subject |
Parasitic capacitance | en_US |
dc.subject |
Capacitors | en_US |
dc.subject |
Transistors | en_US |
dc.subject |
Comparator calibration | en_US |
dc.subject |
kickback noise | en_US |
dc.subject |
parasitic capacitance | en_US |
dc.subject |
sample and hold leakage reduction | en_US |
dc.subject |
SAR ADC | en_US |
dc.title |
A 0.3V 10b 3MS/s SAR ADC With Comparator Calibration and Kickback Noise Reduction for Biomedical Applications | en_US |
dc.type |
Article | en_US |
檔案
本條目沒有附加檔案。
所屬典藏: 期刊論文
引用此條目
Wang, S.-H., & Hung, C.-C. (2020). A 0.3V 10b 3MS/s SAR ADC With Comparator Calibration and Kickback Noise Reduction for Biomedical Applications. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 14(3), 558–569. https://doi.org/10.1109/TBCAS.2020.2982912
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/154497