Influence of Capacitive Coupling on High-Fidelity Non-Contact ECG Measurement
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
9273 | en_US |
dc.citation.issue |
16 | en_US |
dc.citation.spage |
9265 | en_US |
dc.citation.volume |
20 | en_US |
dc.citation.woscount |
0 | en_US |
dc.contributor.author |
Wang, Ting-Wei | en_US |
dc.contributor.author |
Zhang, Hong | en_US |
dc.contributor.author |
Lin, Shien-Fong | en_US |
dc.contributor.department |
分子醫學與生物工程研究所 | zh_TW |
dc.contributor.department |
電機工程學系 | zh_TW |
dc.contributor.department |
Institute of Molecular Medicine and Bioengineering | en_US |
dc.contributor.department |
Department of Electrical and Computer Engineering | en_US |
dc.date.accessioned |
2020-10-05T02:01:06Z | |
dc.date.available |
2020-10-05T02:01:06Z | |
dc.date.issued |
2020-08-01 | en_US |
dc.description.abstract |
Non-contact electrocardiogram (ECG) measurement is an advanced sensing technique that uses capacitive electrodes to detect cardiac signals through non-conductive fabrics. However, the capacitive coupling is a significant factor that affects signal-to-noise ratio (SNR) of non-contact ECG, including skin-electrode active area, material, and thickness of the non-conductive fabric. This study aims to develop a high-fidelity non-contact ECG system to evaluate the influence of capacitive coupling on ECG measurement. In this study, a polymer foam with low surface resistance (0.05 Omega/inch(2)) was designed for improving the capacitive-coupling interface between the curved body and electrode sensing surface. The system recorded excellent non-contact ECG of 29.8dB, and the accuracy of heart rate was 99.5% compared to wet-contact ECG measurement. The SNR exponentially attenuated with decreasing skin-electrode capacitance by the combined evidence of theoretical calculation and experimental results. The proposed system generates distinguishable ECG signals (SNR>0dB) at the skin-electrode capacitance above 85pF and maximum through-thickness of cotton-based cloth of 1.2mm. In conclusion, this study evaluated the influence of capacitive coupling on non-contact ECG measurements and established a lower bound of the coupling capacitance for satisfactory signal quality. Future studies may investigate whether the coupling capacitance can be further reduced. | en_US |
dc.identifier.doi |
10.1109/JSEN.2020.2986723 | en_US |
dc.identifier.issn |
1530-437X | en_US |
dc.identifier.journal |
IEEE SENSORS JOURNAL | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1109/JSEN.2020.2986723 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/155146 | |
dc.identifier.wosnumber |
WOS:000550685000043 | en_US |
dc.language.iso |
en_US | en_US |
dc.subject |
Capacitive electrodes | en_US |
dc.subject |
capacitive coupling | en_US |
dc.subject |
non-contact ECG measurement | en_US |
dc.subject |
polymer foam | en_US |
dc.title |
Influence of Capacitive Coupling on High-Fidelity Non-Contact ECG Measurement | en_US |
dc.type |
Article | en_US |
檔案
本條目沒有附加檔案。
所屬典藏: 期刊論文
引用此條目
Wang, T.-W., Zhang, H., & Lin, S.-F. (2020). Influence of Capacitive Coupling on High-Fidelity Non-Contact ECG Measurement. IEEE SENSORS JOURNAL, 20(16), 9265–9273. https://doi.org/10.1109/JSEN.2020.2986723
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/155146