A Reconfigurable, Pulse-shaping Potentiometric Readout System for Bio-Sensing Transistors
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
5764 | en_US |
dc.citation.spage |
5761 | en_US |
dc.citation.woscount |
0 | en_US |
dc.contributor.author |
Lu, Shao-Yung | en_US |
dc.contributor.author |
Shan, Siang-Sin | en_US |
dc.contributor.author |
Yang, Jiancheng | en_US |
dc.contributor.author |
Chang, Chin-Wei | en_US |
dc.contributor.author |
Ren, Fan | en_US |
dc.contributor.author |
Lin, Jenshan | en_US |
dc.contributor.author |
Pearton, Stephen | en_US |
dc.contributor.author |
Liao, Yu-Te | en_US |
dc.contributor.department |
電機工程學系 | zh_TW |
dc.contributor.department |
Department of Electrical and Computer Engineering | en_US |
dc.date.accessioned |
2020-10-05T02:02:24Z | |
dc.date.available |
2020-10-05T02:02:24Z | |
dc.date.issued |
2019-01-01 | en_US |
dc.description.abstract |
This paper presents a new multi-modality readout system for potentiometric electrochemical sensors. The design adopts a pulse modulation at the gate and drain of the Bio-FET sensors to reduce the effects of charge accumulation between the surface of the electrodes and the ion analytes. The adjustable duration and amplitude of stimuli signals provide flexibility for different biosensing applications and a wide range of detectable concentration. Also, an oscillator-based architecture is proposed for digitization and integration. The counting time can be adjusted to enhance the resolution of the readout system. The proposed potentiometric sensing system was tested with 0.1-10 mM Potassium Ferricyanide (K-3[Fe(CN)(6)]), and the results are interpreted in the micro-LCD on the board. The design offers the opportunity for a handheld medical device with fast and real-time monitoring of biomarkers and ion analytes. | en_US |
dc.identifier.isbn |
978-1-5386-1311-5 | en_US |
dc.identifier.issn |
1557-170X | en_US |
dc.identifier.journal |
2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC) | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/155553 | |
dc.identifier.wosnumber |
WOS:000557295306044 | en_US |
dc.language.iso |
en_US | en_US |
dc.subject |
Electrochemical | en_US |
dc.subject |
potentiometric | en_US |
dc.subject |
Bio-FET | en_US |
dc.subject |
oscillator-based readout | en_US |
dc.title |
A Reconfigurable, Pulse-shaping Potentiometric Readout System for Bio-Sensing Transistors | en_US |
dc.type |
Proceedings Paper | en_US |
檔案
本條目沒有附加檔案。
所屬典藏: 會議論文
引用此條目
Lu, S.-Y., Shan, S.-S., Yang, J., Chang, C.-W., Ren, F., Lin, J., Pearton, S., & Liao, Y.-T. (2019). A Reconfigurable, Pulse-shaping Potentiometric Readout System for Bio-Sensing Transistors. 2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 5761–5764. https://ir.lib.nycu.edu.tw/handle/11536/155553
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/155553