Effect of number of tube rows on the air-side performance of crimped spiral fin-and-tube heat exchanger with a multipass parallel and counter cross-flow configuration
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
1411 | en_US |
dc.citation.issue |
4 | en_US |
dc.citation.spage |
1403 | en_US |
dc.citation.volume |
55 | en_US |
dc.citation.woscount |
9 | |
dc.contributor.author |
Pongsoi, Parinya | en_US |
dc.contributor.author |
Pikulkajorn, Santi | en_US |
dc.contributor.author |
Wang, Chi-Chuan | en_US |
dc.contributor.author |
Wongwises, Somchai | en_US |
dc.contributor.department |
機械工程學系 | zh_TW |
dc.contributor.department |
Department of Mechanical Engineering | en_US |
dc.date.accessioned |
2014-12-08T15:22:05Z | |
dc.date.available |
2014-12-08T15:22:05Z | |
dc.date.issued |
2012-01-31 | en_US |
dc.description.abstract |
The air-side performance of crimped spiral fin and tube heat exchangers at high Reynolds number (3000-13,000) is investigated in this study. The test heat exchangers have a new type of multipass parallel and counter cross-flow water flow arrangement which is a combination of parallel cross-flow and counter cross-flow. The test samples are made from copper and aluminium with different number of tube rows (N-row = 2, 3, 4 and 5). The effects of number of tube rows and fin material on the heat transfer and friction characteristics are studied. The results show that no significant effect for either number of tube rows or fin materials on the heat transfer performance is found at high Reynolds number. In addition, the correlation of the air-side performances of this type of the heat exchangers at high Reynolds number is developed for industrial applications. (c) 2011 Elsevier Ltd. All rights reserved. | en_US |
dc.identifier.doi |
10.1016/j.ijheatmasstransfer.2011.09.064 | en_US |
dc.identifier.issn |
0017-9310 | en_US |
dc.identifier.journal |
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1016/j.ijheatmasstransfer.2011.09.064 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/15674 | |
dc.identifier.wosnumber |
WOS:000300470200088 | |
dc.language.iso |
en_US | en_US |
dc.subject |
Crimped fin | en_US |
dc.subject |
Heat transfer | en_US |
dc.subject |
Heat exchanger | en_US |
dc.subject |
Air-water | en_US |
dc.subject |
Extended surface | en_US |
dc.title |
Effect of number of tube rows on the air-side performance of crimped spiral fin-and-tube heat exchanger with a multipass parallel and counter cross-flow configuration | en_US |
dc.type |
Article | en_US |
檔案
- 000300470200088.pdf (1.62 MB, Adobe PDF)
所屬典藏: 期刊論文
引用此條目
Pongsoi, P., Pikulkajorn, S., Wang, C.-C., & Wongwises, S. (2012). Effect of number of tube rows on the air-side performance of crimped spiral fin-and-tube heat exchanger with a multipass parallel and counter cross-flow configuration. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 55(4), 1403–1411. https://doi.org/10.1016/j.ijheatmasstransfer.2011.09.064
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/15674