Efficacy of Cryoballoon Ablation for Atrial Fibrillation and Recurrence Predictors in an Asian Cohort
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
732 | |
dc.citation.issue |
5 | |
dc.citation.spage |
732 | |
dc.citation.volume |
12 | |
dc.contributor.author |
Wu, Shang-Ju | |
dc.contributor.author |
Li, Cheng-Hung | |
dc.contributor.author |
Weng, Chi-Jen | |
dc.contributor.author |
Lin, Jiunn-Cherng | |
dc.contributor.author |
Chien, Yu-Shan | |
dc.contributor.author |
Chen, Yi-Huei | |
dc.contributor.author |
Lin, Ching-Heng | |
dc.contributor.author |
Hsieh, Yu-Cheng | |
dc.contributor.author |
Huang, Jin-Long | |
dc.contributor.author |
Lo, Li-Wei | |
dc.contributor.author |
Lin, Yenn-Jiang | |
dc.contributor.author |
Chen, Shih-Ann | |
dc.contributor.department |
臨床醫學研究所 | zh_TW |
dc.contributor.department |
醫學系內科學科 | zh_TW |
dc.contributor.department |
Institute of Clinical Medicine | en_US |
dc.contributor.department |
Department of Internal Medicine | en_US |
dc.date.accessioned |
2026-11-27T06:58:26Z | |
dc.date.issued |
2022-04-30 | |
dc.description.abstract |
BACKGROUND: Cryoballoon ablation (CBA) for atrial fibrillation (AF) is a rhythm control procedure used in clinical trials, mostly in Western countries. Its efficacy and the predictors of AF recurrence after CBA remain unclear for Asian populations. We aimed to investigate the efficacy of CBA and the predictors of AF recurrence after CBA in Asian AF patients. METHODS: We included consecutive AF patients undergoing CBA for rhythm control between 2014 and 2020. The baseline characteristics, including AF types, symptom severity, and left atrial diameter (LAD), were analyzed. Holter's monitoring and 12-lead ECG were performed to document AF recurrence. A multivariate Cox hazards regression model was used to evaluate the risk of AF recurrence. RESULTS: A total of 120 AF patients (aged 61.9 ± 9.3 years) were included. The percentage of patients free from AF in the year following CBA was 74.2%. Among the three independent predictors of AF recurrence within one year were the presence of persistent AF (p = 0.025), an LAD ≥ 4.75 cm (p = 0.016), and pre-procedural cardioversion (p = 0.025). All patients survived and none had a stroke after CBA. CONCLUSION: CBA for AF is an effective and safe procedure in Asian populations. The presence of persistent AF, an LAD ≥ 4.75 cm, and severe symptoms are predictors of AF recurrence in the year following CBA. | |
dc.identifier.doi |
10.3390/jpm12050732 | |
dc.identifier.issn |
2075-4426 | |
dc.identifier.journal |
Journal of Personalized Medicine | |
dc.identifier.openalex |
W4225258064 | |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/166262 | |
dc.language.iso |
en_US | |
dc.rights |
CC BY | |
dc.title |
Efficacy of Cryoballoon Ablation for Atrial Fibrillation and Recurrence Predictors in an Asian Cohort | |
dc.type |
Article |
檔案
-
10.3390_jpm12050732.pdf
(890.7 KB, Adobe PDF)
出版社正式版,依 CC BY 授權轉載,來源 https://doi.org/10.3390/jpm12050732
所屬典藏: 期刊論文
引用此條目
Wu, S.-J., Li, C.-H., Weng, C.-J., Lin, J.-C., Chien, Y.-S., Chen, Y.-H., Lin, C.-H., Hsieh, Y.-C., Huang, J.-L., Lo, L.-W., Lin, Y.-J., & Chen, S.-A. (2022). Efficacy of Cryoballoon Ablation for Atrial Fibrillation and Recurrence Predictors in an Asian Cohort. Journal of Personalized Medicine, 12(5), 732. https://doi.org/10.3390/jpm12050732
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/166262