Prediction of residual astigmatism in cataract surgery at different diameter zones using optical biometry measurement
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
4305 | |
dc.citation.issue |
1 | |
dc.citation.spage |
4305 | |
dc.citation.volume |
12 | |
dc.contributor.author |
Chang, Yin-Hsi | |
dc.contributor.author |
Pu, Christy | |
dc.contributor.author |
Lin, Ken-Kuo | |
dc.contributor.author |
Js, Lee | |
dc.contributor.author |
Hou, Chiun-Ho | |
dc.contributor.department |
醫學系 | zh_TW |
dc.contributor.department |
公共衛生研究所 | zh_TW |
dc.contributor.department |
Department of Medicine | en_US |
dc.contributor.department |
Institute of Public Health | en_US |
dc.date.accessioned |
2026-11-27T08:56:02Z | |
dc.date.issued |
2022-03-11 | |
dc.description.abstract |
The studies for astigmatism prediction error at different diameters using optical biometry are scant. We investigated patients who underwent cataract surgery with monofocal, nontoric intraocular lens (IOL) from 2017 through 2019 in a medical center. Patients with prior refractive surgeries, corneal opacity, or surgical complications were excluded. Corneal astigmatism (CA) was measured using AL-Scan at 2.4- and 3.3-mm diameter zones and calculated using the Barrett toric calculator preoperatively and postoperatively. The mean absolute error and centroid prediction error for the two zones were computed using double-angle plots. In total, 101 eyes of 76 patients were analyzed. Mean patient age was 68.7 ± 9.3 years and mean preoperative CA power was 0.7 ± 0.5 D. The overall centroid prediction error a 3.3 mm (0.09 ± 0.58 D@25) was significantly lower than that at 2.4 mm (0.09 ± 0.68 D@87) on the X-axis (P = 0.003). The 3.3-mm measurement also had a lower centroid prediction error than the 2.4-mm did for eyes with against-the-rule (ATR) and oblique astigmatism (P = 0.024; 0.002 on X-axis, respectively). The 3.3-mm measurement provided a more accurate CA estimation than the 2.4-mm did, particularly for ATR astigmatism. Diameter zone and astigmatism type should be considered crucial to precise astigmatism calculation. | |
dc.identifier.doi |
10.1038/s41598-022-08253-6 | |
dc.identifier.issn |
2045-2322 | |
dc.identifier.journal |
Scientific Reports | |
dc.identifier.openalex |
W4221074009 | |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/175207 | |
dc.language.iso |
en_US | |
dc.rights |
CC BY | |
dc.title |
Prediction of residual astigmatism in cataract surgery at different diameter zones using optical biometry measurement | |
dc.type |
Article |
檔案
本條目沒有附加檔案。
所屬典藏: 期刊論文
引用此條目
Chang, Y.-H., Pu, C., Lin, K.-K., Js, L., & Hou, C.-H. (2022). Prediction of residual astigmatism in cataract surgery at different diameter zones using optical biometry measurement. Scientific Reports, 12(1), 4305. https://doi.org/10.1038/s41598-022-08253-6
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/175207