Optimization of Spatial Resolution and Image Reconstruction Parameters for the Small-Animal Metis™ PET/CT System
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
1542 | |
dc.citation.issue |
10 | |
dc.citation.spage |
1542 | |
dc.citation.volume |
11 | |
dc.contributor.author |
Zhao, Jie | |
dc.contributor.author |
Liu, Qiong | |
dc.contributor.author |
Li, Chaofan | |
dc.contributor.author |
Song, Yunfeng | |
dc.contributor.author |
Ying, Zhang | |
dc.contributor.author |
Mejia, Jose | |
dc.contributor.author |
Chen, Jyh-Cheng | |
dc.contributor.department |
生物醫學影像暨放射科學系 | zh_TW |
dc.contributor.department |
Department of Biomedical Imaging and Radiological Sciences | en_US |
dc.date.accessioned |
2026-11-27T08:56:08Z | |
dc.date.issued |
2022-05-11 | |
dc.description.abstract |
Purpose: The aim of this study was to investigate the optimization of the spatial resolution and image reconstruction parameters related to image quality in an iterative reconstruction algorithm for the small-animal Metis™ PET/CT system. Methods: We used a homemade Derenzo phantom to evaluate the image quality using visual assessment, the signal-to-noise ratio, the contrast, the coefficient of variation, and the contrast-to-noise ratio of the 0.8 mm hot rods of eight slices in the center of the phantom PET images. A healthy mouse study was performed to analyze the influence of the optimal reconstruction parameters and the Gaussian post-filter FWHM. Results: In the phantom study, the image quality was the best when the phantom was placed at the end, keeping the central axis parallel to the X-axis of the system, and selecting between 30 and 40 iterations, a 0.314 mm reconstructed voxel size, and a 1.57 mm Gaussian post-filter FWHM. The optimization of the spatial resolution could reach 0.6 mm. In the animal study, it was suitable to choose a voxel size of 0.472 mm, between 30 and 40 iterations, and a 2.36 mm Gaussian post-filter FWHM. Conclusions: Our results indicate that the optimal imaging conditions and reconstruction parameters are very necessary to obtain high-resolution images and quantitative accuracy, especially for the high-precision recognition of tiny lesions. | |
dc.identifier.doi |
10.3390/electronics11101542 | |
dc.identifier.issn |
2079-9292 | |
dc.identifier.journal |
Electronics | |
dc.identifier.openalex |
W4280586081 | |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/175331 | |
dc.language.iso |
en_US | |
dc.rights |
CC BY | |
dc.title |
Optimization of Spatial Resolution and Image Reconstruction Parameters for the Small-Animal Metis™ PET/CT System | |
dc.type |
Article |
檔案
本條目沒有附加檔案。
所屬典藏: 期刊論文
引用此條目
Zhao, J., Liu, Q., Li, C., Song, Y., Ying, Z., Mejia, J., & Chen, J.-C. (2022). Optimization of Spatial Resolution and Image Reconstruction Parameters for the Small-Animal Metis™ PET/CT System. Electronics, 11(10), 1542. https://doi.org/10.3390/electronics11101542
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/175331