Aluminum overload in the reverse osmosis dialysis era: does it exist?
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
1604 | |
dc.citation.issue |
1 | |
dc.citation.spage |
1596 | |
dc.citation.volume |
44 | |
dc.contributor.author |
Chen, Mei-Yin | |
dc.contributor.author |
Ou, Shih-Hsiang | |
dc.contributor.author |
Chen, Nai-Ching | |
dc.contributor.author |
Yin, Chun-Hao | |
dc.contributor.author |
Chen, Chien-Liang | |
dc.contributor.department |
醫學系 | zh_TW |
dc.contributor.department |
Department of Medicine | en_US |
dc.date.accessioned |
2026-11-27T08:56:35Z | |
dc.date.issued |
2022-10-03 | |
dc.description.abstract |
BACKGROUND: Aluminum accumulation is a well-described complication in dialysis patients. Improvements in hemodialysis technology have possibly eliminated the occurrence of aluminum overload. Limited evidence suggests that aluminum overload may decline in the era of aluminum removal from dialysis fluids, even with the use of aluminum binders. METHODS: We examined the data from January 2014 to June 1, 2020, identified through our electronic records, to evaluate the desferrioxamine (DFO) test results for aluminum overload. The presentation and treatment of aluminum overload were recorded. RESULTS: Ninety-nine dialysis patients were enrolled for the DFO test. Forty-seven patients (47.5%) were identified as DFO test positive for aluminum overload, of which 14 (14/47) patients had symptoms, including one patient with an unexplained fracture, eight patients with unexplained anemia despite high-dose erythropoiesis-stimulating agents, and five patients with hypercalcemia (serum calcium >11 mg dL-1). None of the patients with aluminum overload developed encephalopathy. Only four of the 47 patients had microcytic anemia. Patients requiring longer treatments (>10 months versus | |
dc.identifier.doi |
10.1080/0886022x.2022.2104165 | |
dc.identifier.issn |
0886-022X | |
dc.identifier.issn |
1525-6049 | |
dc.identifier.journal |
Renal Failure | |
dc.identifier.openalex |
W4300690855 | |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/175702 | |
dc.language.iso |
en_US | |
dc.rights |
CC BY | |
dc.title |
Aluminum overload in the reverse osmosis dialysis era: does it exist? | |
dc.type |
Article |
檔案
本條目沒有附加檔案。
所屬典藏: 期刊論文
引用此條目
Chen, M.-Y., Ou, S.-H., Chen, N.-C., Yin, C.-H., & Chen, C.-L. (2022). Aluminum overload in the reverse osmosis dialysis era: does it exist?. Renal Failure, 44(1), 1596–1604. https://doi.org/10.1080/0886022x.2022.2104165
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/175702