Outcomes of abdominal false lumen embolization for chronic aortic dissection after prior proximal repair with stent-graft
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
640 | |
dc.citation.issue |
7 | |
dc.citation.spage |
633 | |
dc.citation.volume |
86 | |
dc.contributor.author |
Kuo, Ching-Yuan | |
dc.contributor.author |
Huang, Chun-Yang | |
dc.contributor.author |
Chen, Tai-Wei | |
dc.contributor.author |
Hsu, Hung-Lung | |
dc.contributor.author |
Shih, Chun-Che | |
dc.contributor.author |
Hsu, Chiao-Po | |
dc.contributor.department |
醫學系 | zh_TW |
dc.contributor.department |
Department of Medicine | en_US |
dc.date.accessioned |
2026-11-27T09:29:05Z | |
dc.date.issued |
2023-04-26 | |
dc.description.abstract |
BACKGROUND: Persistent false lumen (FL) perfusion with aneurysmal formation is common after thoracic endovascular aortic repair (TEVAR) for typical extended aortic dissection and is associated with poor outcomes. Endovascular FL embolization (FLE) has recently been tried for treatment of postdissection aortic aneurysm (PDAA). However, most reports address thoracic rather than abdominal FLE. In this study, we present the results of abdominal FLE in patients with residual patent abdominal FL following stent-graft repair for aortic dissection. METHODS: Between 2015 and 2019, 24 patients (mean age: 56.7 ± 11.8 years, range: 40-84 years, 18 male) received endovascular abdominal FLE using vascular plugs, coils, or candy plugs as the main surgery (5 patients) or auxiliary procedure (19 patients) after earlier stent-graft repair for aortic dissection (Type A: 9, Type B: 15). The medical records were reviewed and aortic remodeling was examined comparing the preembolization computed tomography (CT) and the most recent CT before reintervention. RESULTS: Technical success was achieved without any intraoperative complications, early morbidity, or mortality. Median follow-up was 34.4 months (range: 12-71). Regarding thoracic FL, 15 patients exhibited complete thrombosis before the procedure and did not change status thereafter except for 1 patient with distal stent-graft-induced new entry. In the other 9 patients, 6 exhibited increased thrombosis. With regard to the abdominal aorta, increased FL thrombosis only occurred in 8 patients with 3 (12.5%) achieving complete thrombosis. The maximal thoracic aortic diameter did not change (1.4 ± 5.6 mm) statistically, but the abdominal diameter increased significantly (4.3 ± 3.7 mm, p < 0.005). CONCLUSION: From our results, abdominal FLE is a safe procedure. However, covering all the re-entry tears is complex and the possibility of complete FL thrombosis is low. The abdominal aortic diameter appears to become enlarged in these patients. Continuous follow-up is necessary after FLE. | |
dc.identifier.doi |
10.1097/jcma.0000000000000934 | |
dc.identifier.issn |
1726-4901 | |
dc.identifier.issn |
1728-7731 | |
dc.identifier.journal |
Journal of the Chinese Medical Association | |
dc.identifier.openalex |
W4367053985 | |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/178643 | |
dc.language.iso |
en_US | |
dc.rights |
CC BY-NC-ND | |
dc.title |
Outcomes of abdominal false lumen embolization for chronic aortic dissection after prior proximal repair with stent-graft | |
dc.type |
Article |
檔案
-
10.1097_jcma.0000000000000934.pdf
(502.2 KB, Adobe PDF)
出版社正式版,依 CC BY-NC-ND 授權轉載,來源 https://doi.org/10.1097/jcma.0000000000000934
所屬典藏: 期刊論文
引用此條目
Kuo, C.-Y., Huang, C.-Y., Chen, T.-W., Hsu, H.-L., Shih, C.-C., & Hsu, C.-P. (2023). Outcomes of abdominal false lumen embolization for chronic aortic dissection after prior proximal repair with stent-graft. Journal of the Chinese Medical Association, 86(7), 633–640. https://doi.org/10.1097/jcma.0000000000000934
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/178643