UI-Styler: Ultrasound Image Style Transfer with Class-Aware Prompts for Cross-Device Diagnosis Using a Frozen Black-Box Inference Network
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
2774 | |
dc.citation.spage |
2765 | |
dc.contributor.author |
Do-Tran, Nhat-Tuong | |
dc.contributor.author |
Le, Ngoc-Hoang-Lam | |
dc.contributor.author |
Huang, Ching-Chun | |
dc.contributor.department |
陽明交大名義發表 | zh_TW |
dc.contributor.department |
National Yang Ming Chiao Tung University | en_US |
dc.date.accessioned |
2026-11-27T12:38:05Z | |
dc.date.issued |
2026-03-06 | |
dc.description.abstract |
The appearance of ultrasound images varies across acquisition devices, causing domain shifts that degrade the performance of fixed black-box downstream inference models when reused. To mitigate this issue, it is practical to develop unpaired image translation (UIT) methods that effectively align the statistical distributions between source and target domains, particularly under the constraint of a reused inference-blackbox setting. However, existing UIT approaches often overlook class-specific semantic alignment during domain adaptation, resulting in misaligned content-class mappings that can impair diagnostic accuracy. To address this limitation, we propose UI-Styler, a novel ultrasound-specific, class-aware image style transfer framework. UI-Styler leverages a pattern-matching mechanism to transfer texture patterns embedded in the target images onto source images while preserving the source structural content. In addition, we introduce a class-aware prompting strategy guided by pseudo labels of the target domain, which enforces accurate semantic alignment with diagnostic categories. Extensive experiments on ultrasound cross-device tasks demonstrate that UI-Styler consistently outperforms existing UIT methods, achieving state-of-the-art performance in distribution distance and downstream tasks, such as classification and segmentation. | |
dc.identifier.doi |
10.1109/wacv61042.2026.00271 | |
dc.identifier.issn |
2472-6737 | |
dc.identifier.journal |
IEEE Winter Conference on Applications of Computer Vision | |
dc.identifier.openalex |
W4416595906 | |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/192532 | |
dc.language.iso |
en_US | |
dc.rights |
CC BY | |
dc.title |
UI-Styler: Ultrasound Image Style Transfer with Class-Aware Prompts for Cross-Device Diagnosis Using a Frozen Black-Box Inference Network | |
dc.type |
Proceedings Paper |
檔案
本條目沒有附加檔案。
所屬典藏: 會議論文
引用此條目
Do-Tran, N.-T., Le, N.-H.-L., & Huang, C.-C. (2026). UI-Styler: Ultrasound Image Style Transfer with Class-Aware Prompts for Cross-Device Diagnosis Using a Frozen Black-Box Inference Network. IEEE Winter Conference on Applications of Computer Vision, 2765–2774. https://doi.org/10.1109/wacv61042.2026.00271
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/192532