A Wireless and Batteryless Microsystem with Implantable Grid Electrode/3-Dimensional Probe Array for ECoG and Extracellular Neural Recording in Rats
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
4639 | en_US |
dc.citation.issue |
4 | en_US |
dc.citation.spage |
4624 | en_US |
dc.citation.volume |
13 | en_US |
dc.citation.woscount |
4 | |
dc.contributor.author |
Chang, Chih-Wei | en_US |
dc.contributor.author |
Chiou, Jin-Chern | en_US |
dc.contributor.department |
電機資訊學士班 | zh_TW |
dc.contributor.department |
Undergraduate Honors Program of Electrical Engineering and Computer Science | en_US |
dc.date.accessioned |
2014-12-08T15:30:43Z | |
dc.date.available |
2014-12-08T15:30:43Z | |
dc.date.issued |
2013-04-01 | en_US |
dc.description.abstract |
This paper presents the design and implementation of an integrated wireless microsystem platform that provides the possibility to support versatile implantable neural sensing devices in free laboratory rats. Inductive coupled coils with low dropout regulator design allows true long-term recording without limitation of battery capacity. A 16-channel analog front end chip located on the headstage is designed for high channel account neural signal conditioning with low current consumption and noise. Two types of implantable electrodes including grid electrode and 3D probe array are also presented for brain surface recording and 3D biopotential acquisition in the implanted target volume of tissue. The overall system consumes less than 20 mA with small form factor, 3.9 x 3.9 cm(2) mainboard and 1.8 x 3.4 cm(2) headstage, is packaged into a backpack for rats. Practical in vivo recordings including auditory response, brain resection tissue and PZT-induced seizures recording demonstrate the correct function of the proposed microsystem. Presented achievements addressed the aforementioned properties by combining MEMS neural sensors, low-power circuit designs and commercial chips into system-level integration. | en_US |
dc.identifier.doi |
10.3390/s130404624 | en_US |
dc.identifier.issn |
1424-8220 | en_US |
dc.identifier.journal |
SENSORS | en_US |
dc.identifier.uri |
http://dx.doi.org/10.3390/s130404624 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/21943 | |
dc.identifier.wosnumber |
WOS:000318036400038 | |
dc.language.iso |
en_US | en_US |
dc.subject |
microsystem | en_US |
dc.subject |
wireless | en_US |
dc.subject |
neural electrode array | en_US |
dc.subject |
biopotentials | en_US |
dc.title |
A Wireless and Batteryless Microsystem with Implantable Grid Electrode/3-Dimensional Probe Array for ECoG and Extracellular Neural Recording in Rats | en_US |
dc.type |
Article | en_US |
檔案
- 000318036400038.pdf (1.48 MB, Adobe PDF)
所屬典藏: 期刊論文
引用此條目
Chang, C.-W., & Chiou, J.-C. (2013). A Wireless and Batteryless Microsystem with Implantable Grid Electrode/3-Dimensional Probe Array for ECoG and Extracellular Neural Recording in Rats. SENSORS, 13(4), 4624–4639. https://doi.org/10.3390/s130404624
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/21943