Heterodyne moire interferometry for measuring corneal surface profile
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
235 | en_US |
dc.citation.issue |
en_US | |
dc.citation.spage |
232 | en_US |
dc.citation.volume |
54 | en_US |
dc.citation.woscount |
0 | |
dc.contributor.author |
Chang, Wei-Yao | en_US |
dc.contributor.author |
Chen, Kun-Huang | en_US |
dc.contributor.author |
Chen, Der-Chin | en_US |
dc.contributor.author |
Tseng, Jung-Kai | en_US |
dc.contributor.author |
Chen, Shyan-Tarng | en_US |
dc.contributor.author |
Sun, Han-Ying | en_US |
dc.contributor.author |
Chen, Jing-Heng | en_US |
dc.contributor.author |
Hsu, Ken Y. | en_US |
dc.contributor.department |
光電工程學系 | zh_TW |
dc.contributor.department |
Department of Photonics | en_US |
dc.date.accessioned |
2014-12-08T15:33:53Z | |
dc.date.available |
2014-12-08T15:33:53Z | |
dc.date.issued |
2014-03-01 | en_US |
dc.description.abstract |
This study proposes an accurate method for reconstructing the corneal surface profile. By applying a constant velocity to the projection grating along the grating plane, a series of sampling points of the sinusoidal wave, which behaves in the manner of heterodyne interferometric signals, can be recorded using a CMOS camera. The phase distribution of the moire fringes can then be obtained using the IEEE 1241 least-square sine fitting algorithm and two-dimensional (2D) phase unwrapping. Finally, the corneal surface profile can be reconstructed by substituting the phase distribution into a specially derived equation. To validate the proposed method, the corneal surface of a pig eyeball was measured. The measurement resolution was approximately 3.5 mu m. Because of the introduction of the Talbot effect, the projection moire method, and heterodyne interferometry, this approach provides the advantages of a simple optical setup, ease of operation, high stability, and high resolution. (C) 2013 Elsevier Ltd. All rights reserved. | en_US |
dc.identifier.doi |
10.1016/j.optlaseng.2013.07.013 | en_US |
dc.identifier.issn |
0143-8166 | en_US |
dc.identifier.journal |
OPTICS AND LASERS IN ENGINEERING | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1016/j.optlaseng.2013.07.013 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/23366 | |
dc.identifier.wosnumber |
WOS:000328720700029 | |
dc.language.iso |
en_US | en_US |
dc.subject |
Corneal surface profile | en_US |
dc.subject |
Heterodyne interferometry | en_US |
dc.subject |
Projection moire | en_US |
dc.subject |
Talbot effect | en_US |
dc.title |
Heterodyne moire interferometry for measuring corneal surface profile | en_US |
dc.type |
Article | en_US |
檔案
- 000328720700029.pdf (5.22 MB, Adobe PDF)
所屬典藏: 期刊論文
引用此條目
Chang, W.-Y., Chen, K.-H., Chen, D.-C., Tseng, J.-K., Chen, S.-T., Sun, H.-Y., Chen, J.-H., & Hsu, K. Y. (2014). Heterodyne moire interferometry for measuring corneal surface profile. OPTICS AND LASERS IN ENGINEERING, 54, 232–235. https://doi.org/10.1016/j.optlaseng.2013.07.013
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/23366