Effects of N-2 and O-2 annealing on the multianalyte biosensing characteristics of CeO2-based electrolyte-insulator-semiconductor structures
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
510 | en_US |
dc.citation.issue |
en_US | |
dc.citation.spage |
503 | en_US |
dc.citation.volume |
194 | en_US |
dc.citation.woscount |
0 | |
dc.contributor.author |
Kao, Chyuan Haur | en_US |
dc.contributor.author |
Chen, Hsiang | en_US |
dc.contributor.author |
Lee, Ming Ling | en_US |
dc.contributor.author |
Liu, Che Chun | en_US |
dc.contributor.author |
Ueng, Herng-Yih | en_US |
dc.contributor.author |
Chu, Yu Cheng | en_US |
dc.contributor.author |
Chen, Ching Bang | en_US |
dc.contributor.author |
Chang, Kow Ming | en_US |
dc.contributor.department |
電子工程學系及電子研究所 | zh_TW |
dc.contributor.department |
Department of Electronics Engineering and Institute of Electronics | en_US |
dc.date.accessioned |
2014-12-08T15:34:56Z | |
dc.date.available |
2014-12-08T15:34:56Z | |
dc.date.issued |
2014-04-01 | en_US |
dc.description.abstract |
A CeO2-based multi-analyte electrolyte-insulator-semiconductor (EIS) biosensor has been fabricated on silicon substrate. To enhance the material quality and sensing performance, annealing treatment in N-2 and O-2 ambient has been incorporated. To examine the annealing effects, material analyses were conducted using X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM) to identify optimal treatment conditions. Furthermore, sensing performance for various ions of Na+, K+, urea, and glucose has also been tested. Results indicate that the membrane annealed at 800 degrees C in O-2 ambience exhibited a better performance with higher multianalyte sensitivity and a lower drift rate compared with the membrane annealed in N-2 ambience. Oxygen in O-2 ambience may cause stronger reflow and fill in the oxygen vacancy so that the material properties and sensing capability can be improved in O-2 annealing ambience. (C) 2014 Elsevier B.V. All rights reserved. | en_US |
dc.identifier.doi |
10.1016/j.snb.2013.12.103 | en_US |
dc.identifier.issn |
0925-4005 | en_US |
dc.identifier.journal |
SENSORS AND ACTUATORS B-CHEMICAL | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1016/j.snb.2013.12.103 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/23751 | |
dc.identifier.wosnumber |
WOS:000331575400066 | |
dc.language.iso |
en_US | en_US |
dc.subject |
CeO2 | en_US |
dc.subject |
O-2 and N-2 annealing | en_US |
dc.subject |
Electrolyte-insulator-semiconductor | en_US |
dc.subject |
Material quality | en_US |
dc.subject |
Sensing performance | en_US |
dc.title |
Effects of N-2 and O-2 annealing on the multianalyte biosensing characteristics of CeO2-based electrolyte-insulator-semiconductor structures | en_US |
dc.type |
Article | en_US |
檔案
- 000331575400066.pdf (3.66 MB, Adobe PDF)
所屬典藏: 期刊論文
引用此條目
Kao, C. H., Chen, H., Lee, M. L., Liu, C. C., Ueng, H.-Y., Chu, Y. C., Chen, C. B., & Chang, K. M. (2014). Effects of N-2 and O-2 annealing on the multianalyte biosensing characteristics of CeO2-based electrolyte-insulator-semiconductor structures. SENSORS AND ACTUATORS B-CHEMICAL, 194, 503–510. https://doi.org/10.1016/j.snb.2013.12.103
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/23751