Collimation testing and calibration using a heterodyne Moire method
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
131 | en_US |
dc.citation.issue |
en_US | |
dc.citation.spage |
126 | en_US |
dc.citation.volume |
62 | en_US |
dc.citation.woscount |
2 | |
dc.contributor.author |
Chang, Wei-Yao | en_US |
dc.contributor.author |
Hsu, Ken Y. | en_US |
dc.contributor.author |
Chen, Kun-Huang | en_US |
dc.contributor.author |
Chen, Jing-Heng | en_US |
dc.contributor.department |
光電工程學系 | zh_TW |
dc.contributor.department |
Department of Photonics | en_US |
dc.date.accessioned |
2014-12-08T15:36:27Z | |
dc.date.available |
2014-12-08T15:36:27Z | |
dc.date.issued |
2014-11-01 | en_US |
dc.description.abstract |
This study proposes a simple, rapid, and highly accurate method to achieve the collimation testing and calibration of laser light beams. By applying a relative constant velocity to two gratings, every pixel of a CMOS camera can receive a series of heterodyne moire signals. Based on the least squares sine fitting algorithm, the phase of the optimized sinusoidal wave can be obtained. Consequently, the phase slope along the direction perpendicular to the grating lines can be estimated and then used to judge the degree of collimation. Furthermore, by measuring only two phase slopes at two positions of the collimating lens, the calibration of the light beam collimation can also be achieved. The experiment validated the proposed method, and the positioning error of the light beam collimation was approximately 7 mu m. (C) 2014 Elsevier Ltd. All rights reserved. | en_US |
dc.identifier.doi |
10.1016/j.optlaseng.2014.06.001 | en_US |
dc.identifier.issn |
0143-8166 | en_US |
dc.identifier.journal |
OPTICS AND LASERS IN ENGINEERING | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1016/j.optlaseng.2014.06.001 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/24799 | |
dc.identifier.wosnumber |
WOS:000339696600015 | |
dc.language.iso |
en_US | en_US |
dc.subject |
Collimation testing | en_US |
dc.subject |
Moire interferometry | en_US |
dc.subject |
Talbot effect | en_US |
dc.subject |
Heterodyne interferometry | en_US |
dc.title |
Collimation testing and calibration using a heterodyne Moire method | en_US |
dc.type |
Article | en_US |
檔案
- 000339696600015.pdf (1.91 MB, Adobe PDF)
所屬典藏: 期刊論文
引用此條目
Chang, W.-Y., Hsu, K. Y., Chen, K.-H., & Chen, J.-H. (2014). Collimation testing and calibration using a heterodyne Moire method. OPTICS AND LASERS IN ENGINEERING, 62, 126–131. https://doi.org/10.1016/j.optlaseng.2014.06.001
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/24799