Human Cognitive Application by Using Wearable Mobile Brain Computer Interface
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
351 | en_US |
dc.citation.spage |
346 | en_US |
dc.contributor.author |
Liao, Lun-De | en_US |
dc.contributor.author |
Wang, I-Jan | en_US |
dc.contributor.author |
Chang, Che-Jui | en_US |
dc.contributor.author |
Lin, Bor-Shyh | en_US |
dc.contributor.author |
Lin, Chin-Teng | en_US |
dc.contributor.author |
Tseng, Kevin C. | en_US |
dc.contributor.department |
電機工程學系 | zh_TW |
dc.contributor.department |
Department of Electrical and Computer Engineering | en_US |
dc.date.accessioned |
2014-12-08T15:36:38Z | |
dc.date.available |
2014-12-08T15:36:38Z | |
dc.date.issued |
2010 | en_US |
dc.description.abstract |
In this study, we demonstrated a Wearable Mobile Electroencephalogram (EEG)-based Brain Computer Interface System (WMEBCIS) with foam-based dry electrodes embedded. According to the previous studies, many kinds of BCI systems have been proposed and target the applications on sensors and information techniques. For daily life EEG monitoring by using the BCI systems, the sensors have employ a key technique for ensuring the data quality. In view of this, a novel dry foam electrode was designed and applied for the wearable EEG acquisition device in our WMEBCIS. The developed dry electrodes can achieve the quick-placement and high signals quality under no skin preparation and without gels applied. Most importantly, due to its softness advantage, the developed electrodes can fit properly on the skin surface to maintain low skin-electrode impedance and reduce motion artifacts under movement. By using the specific mechanism of our wearable EEG acquisition device, it can be worn conveniently and can maintain the electrode-scalp contact area to acquire good EEG signal quality effectively. Therefore, the wearable EEG acquisition device is suitable for long-term EEG monitoring in daily life. In words, our WMEBCIS was also demonstrated for a cognitive application on drowsiness detection. | en_US |
dc.identifier.isbn |
978-1-4244-6890-4 | en_US |
dc.identifier.issn |
0886-1420 | en_US |
dc.identifier.journal |
TENCON 2010: 2010 IEEE REGION 10 CONFERENCE | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/24988 | |
dc.identifier.wosnumber |
WOS:000287978600056 | |
dc.language.iso |
en_US | en_US |
dc.subject |
EEG | en_US |
dc.subject |
Bio-sensor | en_US |
dc.subject |
Injection molding | en_US |
dc.subject |
Brain computer interface | en_US |
dc.title |
Human Cognitive Application by Using Wearable Mobile Brain Computer Interface | en_US |
dc.type |
Article | en_US |
檔案
本條目沒有附加檔案。
所屬典藏: 會議論文
引用此條目
Liao, L.-D., Wang, I.-J., Chang, C.-J., Lin, B.-S., Lin, C.-T., & Tseng, K. C. (2010). Human Cognitive Application by Using Wearable Mobile Brain Computer Interface. TENCON 2010: 2010 IEEE REGION 10 CONFERENCE, 346–351. https://ir.lib.nycu.edu.tw/handle/11536/24988
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/24988