Mixed Bio-Signal Lossless Data Compressor for Portable Brain-Heart Monitoring Systems
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
273 | en_US |
dc.citation.issue |
1 | en_US |
dc.citation.spage |
267 | en_US |
dc.citation.volume |
57 | en_US |
dc.citation.woscount |
12 | |
dc.contributor.author |
Chua, Ericson | en_US |
dc.contributor.author |
Fang, Wai-Chi | en_US |
dc.contributor.department |
電子工程學系及電子研究所 | zh_TW |
dc.contributor.department |
Department of Electronics Engineering and Institute of Electronics | en_US |
dc.date.accessioned |
2014-12-08T15:37:28Z | |
dc.date.available |
2014-12-08T15:37:28Z | |
dc.date.issued |
2011-02-01 | en_US |
dc.description.abstract |
This paper presents a highly integrated VLSI implementation of a mixed bio-signal lossless data compressor capable of handling multichannel electroencephalogram (EEG), electrocardiogram (ECG) and diffuse optical tomography (DOT) bio-signal data for reduced storage and communication bandwidth requirements in portable, wireless brain-heart monitoring systems used in hospital or home care settings. The compressor integrated in a multiprocessor brain-heart monitoring IC comprises 15k gates and 12kbits of RAM, occupying a total area of 58k mu m(2) in 65nm CMOS technology. Results demonstrate an average compression ratio (CR) of 2.05, and a simulated power consumption of 170 mu W at an operating condition of 24MHz clock and 1.0V core voltage. Nominal power savings of 43% and 47% at the transmitter can be achieved when employing Bluetooth and Zigbee transceivers, respectively(1). | en_US |
dc.identifier.doi |
10.1109/TCE.2011.5735512 | en_US |
dc.identifier.issn |
0098-3063 | en_US |
dc.identifier.journal |
IEEE TRANSACTIONS ON CONSUMER ELECTRONICS | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1109/TCE.2011.5735512 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/25782 | |
dc.identifier.wosnumber |
WOS:000288676900039 | |
dc.language.iso |
en_US | en_US |
dc.subject |
Biomedical signal processing | en_US |
dc.subject |
lossless data compression | en_US |
dc.subject |
electroencephalogram (EEG) | en_US |
dc.subject |
electrocardiogram (ECG) | en_US |
dc.subject |
diffuse optical tomography (DOT) | en_US |
dc.title |
Mixed Bio-Signal Lossless Data Compressor for Portable Brain-Heart Monitoring Systems | en_US |
dc.type |
Article | en_US |
檔案
- 000288676900039.pdf (667.0 KB, Adobe PDF)
所屬典藏: 期刊論文
引用此條目
Chua, E., & Fang, W.-C. (2011). Mixed Bio-Signal Lossless Data Compressor for Portable Brain-Heart Monitoring Systems. IEEE TRANSACTIONS ON CONSUMER ELECTRONICS, 57(1), 267–273. https://doi.org/10.1109/TCE.2011.5735512
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/25782