THE BEHAVIOR OF BILATERAL LATCH-UP TRIGGERING IN VLSI ELECTROSTATIC DISCHARGE DAMAGE PROTECTION CIRCUITS
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
4933 | en_US |
dc.citation.issue |
11A | en_US |
dc.citation.spage |
4928 | en_US |
dc.citation.volume |
32 | en_US |
dc.citation.woscount |
0 | |
dc.contributor.author |
HUANG, HS | en_US |
dc.contributor.author |
CHANG, CY | en_US |
dc.contributor.author |
HSU, CC | en_US |
dc.contributor.author |
CHEN, KL | en_US |
dc.contributor.author |
LIN, JK | en_US |
dc.contributor.department |
電控工程研究所 | zh_TW |
dc.contributor.department |
Institute of Electrical and Control Engineering | en_US |
dc.date.accessioned |
2014-12-08T15:04:18Z | |
dc.date.available |
2014-12-08T15:04:18Z | |
dc.date.issued |
1993-11-01 | en_US |
dc.description.abstract |
A new latch-up phenomenon that shows symmetrical diac I-V characteristics has been discovered recently. Electrical measurements show that a diac parasitic semiconductor-controlled-rectifier (SCR) device can exist between two adjacent electro static discharge damage (ESD) protection circuits or output buffers. The SCR consists of two parasitic P-N-P-N paths and can easily induce a localized SCR latch-up between two adjacent input or output terminals. This is not similar to traditional latch-up that creates a parasitic P-N-P-N path between power supply and ground pins, but is a new bilateral latch-up path between two adjacent input and output pins. A new latch-up failure mode due to this diac structure, which creates a bilateral path during temperature humidity bias (THB) testing, is discussed. Some suggestions regarding the improvement of this diac latch-up degradation are proposed. Advanced analyses and modeling are also presented in this paper. The modified diac latch-up lumped element model successfull explains this phenomenon. | en_US |
dc.identifier.doi |
10.1143/JJAP.32.4928 | en_US |
dc.identifier.issn |
0021-4922 | en_US |
dc.identifier.journal |
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1143/JJAP.32.4928 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/2805 | |
dc.identifier.wosnumber |
WOS:A1993ML96600013 | |
dc.language.iso |
en_US | en_US |
dc.subject |
VLSI | en_US |
dc.subject |
ESD | en_US |
dc.subject |
LATCH-UP | en_US |
dc.subject |
DIAC | en_US |
dc.subject |
SCR AND BILATERAL | en_US |
dc.title |
THE BEHAVIOR OF BILATERAL LATCH-UP TRIGGERING IN VLSI ELECTROSTATIC DISCHARGE DAMAGE PROTECTION CIRCUITS | en_US |
dc.type |
Article | en_US |
檔案
- A1993ML96600013.pdf (735.4 KB, Adobe PDF)
所屬典藏: 期刊論文
引用此條目
HUANG, H., CHANG, C., HSU, C., CHEN, K., & LIN, J. (1993). THE BEHAVIOR OF BILATERAL LATCH-UP TRIGGERING IN VLSI ELECTROSTATIC DISCHARGE DAMAGE PROTECTION CIRCUITS. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 32(11A), 4928–4933. https://doi.org/10.1143/JJAP.32.4928
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/2805