dc.description.abstract |
In this paper, results from fire resistance experiments on five types of reinforced concrete columns are presented. The variables considered in the study include concrete strength [normal-strength concrete (NSC) and high-strength concrete (HSC)], aggregate type (siliceous and carbonate aggregate), and fiber reinforcement (steel and polypropylene fibers). Data from the study is used to determine the structural behavior of HSC columns at elevated temperatures. A comparison is made of the fire resistance performance of HSC columns with that of NSC and fiber-reinforced HSC columns. The factors that influence the thermal and structural behavior of HSC concrete columns under fire conditions are discussed. The results show that the fire resistance of a NSC column is higher than that of a HSC column. Also, the addition of polypropylene fibers and the use of carbonate aggregate improve fire resistance. | en_US |
dc.identifier.doi |
10.1061/(ASCE)0733-9445(2003)129:2(253) | en_US |
dc.identifier.issn |
0733-9445 | en_US |
dc.identifier.journal |
JOURNAL OF STRUCTURAL ENGINEERING-ASCE | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1061/(ASCE)0733-9445(2003)129:2(253) | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/28135 | |
dc.identifier.wosnumber |
WOS:000180490700014 | |
dc.language.iso |
en_US | en_US |
dc.subject |
fire resistance | en_US |
dc.subject |
high-strength concrete | en_US |
dc.subject |
concrete columns | en_US |
dc.subject |
temperature | en_US |
dc.subject |
fiber-reinforced materials | en_US |
dc.title |
Effect of strength and fiber reinforcement on fire resistance of high-strength concrete columns | en_US |
dc.type |
Article | en_US |
檔案
- 000180490700014.pdf (236.0 KB, Adobe PDF)
所屬典藏: 期刊論文
引用此條目
Kodur, V., Cheng, F., Wang, T., & Sultan, M. (2003). Effect of strength and fiber reinforcement on fire resistance of high-strength concrete columns. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 129(2), 253–259. https://doi.org/10.1061/(ASCE)0733-9445(2003)129:2(253)
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/28135