A dual-snake model of high penetrability for ultrasound image boundary extraction
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
1665 | en_US |
dc.citation.issue |
12 | en_US |
dc.citation.spage |
1651 | en_US |
dc.citation.volume |
27 | en_US |
dc.citation.woscount |
19 | |
dc.contributor.author |
Chen, CM | en_US |
dc.contributor.author |
Lu, HHS | en_US |
dc.contributor.author |
Hsiao, AT | en_US |
dc.contributor.department |
統計學研究所 | zh_TW |
dc.contributor.department |
Institute of Statistics | en_US |
dc.date.accessioned |
2014-12-08T15:43:10Z | |
dc.date.available |
2014-12-08T15:43:10Z | |
dc.date.issued |
2001-12-01 | en_US |
dc.description.abstract |
Most deformable models require the initial contour to be placed close to the boundary of the object of interest for boundary extraction of ultrasound (US) images, which is impractical in many clinical applications. To allow a distant initial contour, a new dual-snake model promising high penetrability through the interference of the noises is proposed in this paper. The proposed dual-snake model features a new far-reaching external force, called the discrete gradient flow, a connected component-weighted image force, and an effective stability evaluation of two underlying snakes. The experimental results show that, with a distant initial contour, the mean distance from the derived boundary to the desired boundary is less than 1.4 pixels, and most snake elements are within 2.7 pixels of the desired boundaries for the synthetic images with CNR greater than or equal to 1. For the clinical US images, the mean distance is less than 1.9 pixels, and most snake elements are within 3 pixels of the desired boundaries. (E-mail: chung@lotus.mc.ntu.edu.tw) (C) 2002 World Federation for Ultrasound in Medicine Biology. | en_US |
dc.identifier.doi |
10.1016/S0301-5629(01)00484-7 | en_US |
dc.identifier.issn |
0301-5629 | en_US |
dc.identifier.journal |
ULTRASOUND IN MEDICINE AND BIOLOGY | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1016/S0301-5629(01)00484-7 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/29217 | |
dc.identifier.wosnumber |
WOS:000174007900008 | |
dc.language.iso |
en_US | en_US |
dc.subject |
boundary extraction | en_US |
dc.subject |
ultrasound images | en_US |
dc.subject |
deformable model | en_US |
dc.subject |
dual-snake model | en_US |
dc.subject |
discrete gradient glow | en_US |
dc.subject |
connected components | en_US |
dc.subject |
stability | en_US |
dc.title |
A dual-snake model of high penetrability for ultrasound image boundary extraction | en_US |
dc.type |
Article | en_US |
檔案
本條目沒有附加檔案。
所屬典藏: 期刊論文
引用此條目
Chen, C., Lu, H., & Hsiao, A. (2001). A dual-snake model of high penetrability for ultrasound image boundary extraction. ULTRASOUND IN MEDICINE AND BIOLOGY, 27(12), 1651–1665. https://doi.org/10.1016/S0301-5629(01)00484-7
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/29217