Copper voids improvement for the copper dual damascene interconnection process
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
571 | en_US |
dc.citation.issue |
2-3 | en_US |
dc.citation.spage |
566 | en_US |
dc.citation.volume |
69 | en_US |
dc.contributor.author |
Wang, T. C. | en_US |
dc.contributor.author |
Wang, Y. L. | en_US |
dc.contributor.author |
Hsieh, T. E. | en_US |
dc.contributor.author |
Chang, S. C. | en_US |
dc.contributor.author |
Cheng, Y. L. | en_US |
dc.contributor.department |
材料科學與工程學系 | zh_TW |
dc.contributor.department |
Department of Materials Science and Engineering | en_US |
dc.date.accessioned |
2014-12-08T15:44:45Z | |
dc.date.available |
2014-12-08T15:44:45Z | |
dc.date.issued |
2008-02-01 | en_US |
dc.description.abstract |
The mechanism of copper (Cu) voids formation from electro-chemical plating (ECP) followed by Cu chemical mechanical polishing (CMP) are studied in Cu dual-damascene interconnection. The formation of Cu voids at metal lines is the main problem that causes not only the failure of via-induced metal-island corrosion but also yield loss. The galvanic theory and Cu lifting mechanism are proposed to explain the dependence of Cu-void performance on the Cu grain size and the benzotriazole (BTA, C6H5N3) flow rates. In the integration process of Cu interconnects, it is found that the smaller Cu grain size in ECP conditions and less BTA flow rate in CMP processes cannot only reduce the number of Cu voids but also improve the water yield. (c) 2007 Elsevier Ltd. All rights reserved. | en_US |
dc.identifier.doi |
10.1016/j.jpcs.2007.07.119 | en_US |
dc.identifier.issn |
0022-3697 | en_US |
dc.identifier.journal |
JOURNAL OF PHYSICS AND CHEMISTRY OF SOLIDS | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1016/j.jpcs.2007.07.119 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/30209 | |
dc.identifier.wosnumber |
WOS:000253874700066 | |
dc.language.iso |
en_US | en_US |
dc.subject |
semiconductors | en_US |
dc.subject |
thin films | en_US |
dc.subject |
defects | en_US |
dc.subject |
electrical properties | en_US |
dc.title |
Copper voids improvement for the copper dual damascene interconnection process | en_US |
dc.type |
Article; Proceedings Paper | en_US |
檔案
- 000253874700066.pdf (1.43 MB, Adobe PDF)
所屬典藏: 會議論文
引用此條目
Wang, T. C., Wang, Y. L., Hsieh, T. E., Chang, S. C., & Cheng, Y. L. (2008). Copper voids improvement for the copper dual damascene interconnection process. JOURNAL OF PHYSICS AND CHEMISTRY OF SOLIDS, 69(2-3), 566–571. https://doi.org/10.1016/j.jpcs.2007.07.119
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/30209