Optimum conditions for novel one-step cleaning method for pre-gate oxide cleaning using robust design methodology
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
5808 | en_US |
dc.citation.issue |
10 | en_US |
dc.citation.spage |
5805 | en_US |
dc.citation.volume |
39 | en_US |
dc.citation.woscount |
2 | |
dc.contributor.author |
Pan, TM | en_US |
dc.contributor.author |
Lei, TF | en_US |
dc.contributor.author |
Chao, TS | en_US |
dc.contributor.author |
Liaw, MC | en_US |
dc.contributor.author |
Lu, CP | en_US |
dc.contributor.department |
電子工程學系及電子研究所 | zh_TW |
dc.contributor.department |
Department of Electronics Engineering and Institute of Electronics | en_US |
dc.date.accessioned |
2014-12-08T15:44:47Z | |
dc.date.available |
2014-12-08T15:44:47Z | |
dc.date.issued |
2000-10-01 | en_US |
dc.description.abstract |
A novel one-step cleaning method has been developed for pre-gate-oxide cleaning to replace the conventional RCA two-step cleaning process. Tetramethyl ammonium hydroxide (TMAH) and ethylenediamine tetraacetic acid (EDTA) are added into the RCA SC-1 cleaning solution to enhance cleaning efficiency. We adapt a robust design methodology (Genichi Taguchi method) to analyze the results of our experiments. Using this novel method, it is found that the optimum conditions are A(1)B(2)C(1)D(1) (A(1): TMAH : NH4OH = 1 : 50, B-2: EDTA concentration is 100 ppm, C-1: cleaning time is 5 min, and D-1: cleaning temperature is 60 degreesC). This novel one-step cleaning method is very promising for future large-sized silicon wafer cleaning processes because it has the advantages of reduced processing time and temperature, cost reduction due to reduced chemical usage and improved performance. | en_US |
dc.identifier.issn |
0021-4922 | en_US |
dc.identifier.journal |
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/30237 | |
dc.identifier.wosnumber |
WOS:000090139000017 | |
dc.language.iso |
en_US | en_US |
dc.subject |
RCA | en_US |
dc.subject |
TMAH | en_US |
dc.subject |
EDTA | en_US |
dc.subject |
surface roughness | en_US |
dc.subject |
leakage current | en_US |
dc.subject |
electric breakdown field (E-bd) and charge-to-breakdown (Q(bd)) | en_US |
dc.title |
Optimum conditions for novel one-step cleaning method for pre-gate oxide cleaning using robust design methodology | en_US |
dc.type |
Article | en_US |
檔案
- 000090139000017.pdf (735.4 KB, Adobe PDF)
所屬典藏: 期刊論文
引用此條目
Pan, T., Lei, T., Chao, T., Liaw, M., & Lu, C. (2000). Optimum conditions for novel one-step cleaning method for pre-gate oxide cleaning using robust design methodology. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 39(10), 5805–5808. https://ir.lib.nycu.edu.tw/handle/11536/30237
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/30237