Improvement of CO tolerance of proton exchange membrane fuel cell by an air-bleeding technique
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
en_US | |
dc.citation.issue |
1 | en_US |
dc.citation.volume |
5 | en_US |
dc.contributor.author |
Chen, Chiun-Hsun | en_US |
dc.contributor.author |
Chung, Chen-Chung | en_US |
dc.contributor.author |
Lin, Hsiang-Hui | en_US |
dc.contributor.author |
Yan, Yi-Yie | en_US |
dc.contributor.department |
機械工程學系 | zh_TW |
dc.contributor.department |
Department of Mechanical Engineering | en_US |
dc.date.accessioned |
2014-12-08T15:44:50Z | |
dc.date.available |
2014-12-08T15:44:50Z | |
dc.date.issued |
2008-02-01 | en_US |
dc.description.abstract |
This study investigates the improvement of proton exchange membrane fuel cell (PEMFC) carbon monoxide by periodic air dosing. The carbon monoxide in the fuel gas leads to a significant loss in power. density due to CO poisoning in the anode. The method involves bleeding air into the anode fuel stream (H(2)-CO), which contains CO in various concentrations (20 ppm, 52.7 ppm, and 100 ppm). In the transient CO poisoning test, air bleeding is performed for four different periodic air dosing and cell voltage is fixed at 0.6 V. The result of a dosing of air for 10 s in intervals of 10 s is similar to that of continuous air bleeding except for 100 ppm CO. The CO tolerance of the fuel cell and cell performance recovery from poisoning can be improved by air bleeding. | en_US |
dc.identifier.doi |
10.1115/1.2784278 | en_US |
dc.identifier.issn |
1550-624X | en_US |
dc.identifier.journal |
JOURNAL OF FUEL CELL SCIENCE AND TECHNOLOGY | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1115/1.2784278 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/30264 | |
dc.identifier.wosnumber |
WOS:000253629300017 | |
dc.language.iso |
en_US | en_US |
dc.subject |
air bleeding | en_US |
dc.subject |
CO tolerance | en_US |
dc.subject |
PEMFC | en_US |
dc.subject |
periodic | en_US |
dc.title |
Improvement of CO tolerance of proton exchange membrane fuel cell by an air-bleeding technique | en_US |
dc.type |
Article; Proceedings Paper | en_US |
檔案
本條目沒有附加檔案。
所屬典藏: 會議論文
引用此條目
Chen, C.-H., Chung, C.-C., Lin, H.-H., & Yan, Y.-Y. (2008). Improvement of CO tolerance of proton exchange membrane fuel cell by an air-bleeding technique. JOURNAL OF FUEL CELL SCIENCE AND TECHNOLOGY, 5(1). https://doi.org/10.1115/1.2784278
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/30264