Analysis of Relationship between Inorganic Gases and Fine Particles in Cleanroom Environment
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
254 | en_US |
dc.citation.issue |
3 | en_US |
dc.citation.spage |
245 | en_US |
dc.citation.volume |
10 | en_US |
dc.citation.woscount |
5 | |
dc.contributor.author |
Lin, I-Kai | en_US |
dc.contributor.author |
Bai, Hsunling | en_US |
dc.contributor.author |
Wu, Bi-Jun | en_US |
dc.contributor.department |
環境工程研究所 | zh_TW |
dc.contributor.department |
Institute of Environmental Engineering | en_US |
dc.date.accessioned |
2014-12-08T15:06:51Z | |
dc.date.available |
2014-12-08T15:06:51Z | |
dc.date.issued |
2010-06-01 | en_US |
dc.description.abstract |
The concentrations and characteristics of major components in inorganic gases and fine particles were measured at the photo and etch cleanroom areas in a Taiwan semiconductor factory. The results showed that the major inorganic gases, as expressed in terms of volume concentration, were NH(3) and HF at 7-10 and 4-6 ppbv, respectively. The average PM(2.5) mass concentration were 17.52 and 18.23 mu g/m(3) at the photo and etch areas, respectively, with species of Na(+), NH(4)(+), Cl(-) and SO(4)(2-) had the highest concentrations in the PM(2.5) mass. And the inorganic species account for 56% and 62% of the particulate mass, respectively, at the photo and etch areas. Relatively stronger correlations were observed between NH(4)(+) and SO(4)(2-) with the correlation coefficient R(2) of 0.62 and 0.82, respectively, at the photo and etch areas; this indicates their common source was possibly from the gas to particle formation process. And NH(3) was found to co-exist with HF at the etch area due to their common source as process chemicals (NH(4)OH and HF) in the wet bench. In the predominant NH(3)-rich environment, ammonia is the basic neutralizing agent to form the ammonium aerosol in a cleanroom. | en_US |
dc.identifier.doi |
10.4209/aaqr.2009.10.0065 | en_US |
dc.identifier.issn |
1680-8584 | en_US |
dc.identifier.journal |
AEROSOL AND AIR QUALITY RESEARCH | en_US |
dc.identifier.uri |
http://dx.doi.org/10.4209/aaqr.2009.10.0065 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/5371 | |
dc.identifier.wosnumber |
WOS:000276455900005 | |
dc.language.iso |
en_US | en_US |
dc.subject |
Diffusion denuder system (DDS) | en_US |
dc.subject |
AMCs (Airborne Molecular Contaminants) | en_US |
dc.subject |
Micro-contamination | en_US |
dc.subject |
Cleanroom | en_US |
dc.subject |
Semiconductor device | en_US |
dc.title |
Analysis of Relationship between Inorganic Gases and Fine Particles in Cleanroom Environment | en_US |