DESIGN OF AN AUTOMATED FEEDBACK CONTROL COOLING SYSTEM FOR SWIR LINEAR IMAGE SENSOR APPLICATION
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
246 | en_US |
dc.citation.issue |
3 | en_US |
dc.citation.spage |
234 | en_US |
dc.citation.volume |
38 | en_US |
dc.citation.woscount |
0 | |
dc.contributor.author |
Chen, Chien-Hung | en_US |
dc.contributor.author |
Chen, Chih-Wen | en_US |
dc.contributor.author |
Lin, Chun-Fu | en_US |
dc.contributor.author |
Liao, Tai-Shan | en_US |
dc.contributor.author |
Hwang, Chi-Hung | en_US |
dc.contributor.author |
Lin, Shir-Kuan | en_US |
dc.contributor.department |
電控工程研究所 | zh_TW |
dc.contributor.department |
Institute of Electrical and Control Engineering | en_US |
dc.date.accessioned |
2014-12-08T15:08:00Z | |
dc.date.available |
2014-12-08T15:08:00Z | |
dc.date.issued |
2010 | en_US |
dc.description.abstract |
Our novel automated feedback temperature controlled cooling system consists of a temperature measurement circuit, a TE cooler, a thermistor, a microcontroller, and a digital-to-analog converter and PWM algorithms. The measurement accuracy of this temperature controlled TE system was better than 0.1 degrees C and can be used for maintaining an instrument's isothermal applications. The experimental results of SWIR linear image shows that the temperature can be stably maintained at -20 degrees C, the dark output current can be reduced almost 80mV (Integration time: 100 ms) and the SNR of pixel can be improved from 48dB to 83dB as well. | en_US |
dc.identifier.doi |
10.1080/10739141003707840 | en_US |
dc.identifier.issn |
1073-9149 | en_US |
dc.identifier.journal |
INSTRUMENTATION SCIENCE & TECHNOLOGY | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1080/10739141003707840 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/6283 | |
dc.identifier.wosnumber |
WOS:000277474200004 | |
dc.language.iso |
en_US | en_US |
dc.subject |
automated feedback | en_US |
dc.subject |
PWM | en_US |
dc.subject |
SNR | en_US |
dc.subject |
SWIR linear image | en_US |
dc.subject |
TE cooler | en_US |
dc.subject |
temperature control | en_US |
dc.title |
DESIGN OF AN AUTOMATED FEEDBACK CONTROL COOLING SYSTEM FOR SWIR LINEAR IMAGE SENSOR APPLICATION | en_US |
dc.type |
Article | en_US |
檔案
- 000277474200004.pdf (713.7 KB, Adobe PDF)
所屬典藏: 期刊論文
引用此條目
Chen, C.-H., Chen, C.-W., Lin, C.-F., Liao, T.-S., Hwang, C.-H., & Lin, S.-K. (2010). DESIGN OF AN AUTOMATED FEEDBACK CONTROL COOLING SYSTEM FOR SWIR LINEAR IMAGE SENSOR APPLICATION. INSTRUMENTATION SCIENCE & TECHNOLOGY, 38(3), 234–246. https://doi.org/10.1080/10739141003707840
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/6283