AN AFFINITY SENSOR IMPROVED BY EWOD ACTUATOR-BASED MICROFLUIDIC CHIP
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
465 | en_US |
dc.citation.issue |
6 | en_US |
dc.citation.spage |
461 | en_US |
dc.citation.volume |
21 | en_US |
dc.citation.woscount |
0 | |
dc.contributor.author |
Liu, Chin-Wei | en_US |
dc.contributor.author |
Lin, Chi-Chang | en_US |
dc.contributor.author |
Chen, Li-Chia | en_US |
dc.contributor.author |
Fan, Shih-Kang | en_US |
dc.contributor.author |
Chang, Hsien-Chang | en_US |
dc.contributor.department |
材料科學與工程學系奈米科技碩博班 | zh_TW |
dc.contributor.department |
Graduate Program of Nanotechnology , Department of Materials Science and Engineering | en_US |
dc.date.accessioned |
2014-12-08T15:08:12Z | |
dc.date.available |
2014-12-08T15:08:12Z | |
dc.date.issued |
2009-12-01 | en_US |
dc.description.abstract |
We propose an improved immunoassay method with EWOD-based microfluidic biochip. Electro-wetting on dielectric (EWOD) is based on contact angle-changed phenomenon of droplet on the channel surface. The reactant-containing droplet can be moved from reservoir to a modified electrode area, which a stir function can be provided by controlling AC electro-osmosis flow (ACEOF). The immunochemistry reaction takes place on our modified area via electro-wetting actuation, and the signal from fluorescent or electrochemical impedance spectroscopy (EIS) was used to confirm the performance of designed element. | en_US |
dc.identifier.doi |
10.4015/S1016237209001659 | en_US |
dc.identifier.issn |
1016-2372 | en_US |
dc.identifier.journal |
BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS | en_US |
dc.identifier.uri |
http://dx.doi.org/10.4015/S1016237209001659 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/6395 | |
dc.identifier.wosnumber |
WOS:000272918500022 | |
dc.language.iso |
en_US | en_US |
dc.subject |
Microfluidics | en_US |
dc.subject |
Immunoassay | en_US |
dc.subject |
Impedance | en_US |
dc.subject |
Electro-wetting | en_US |
dc.title |
AN AFFINITY SENSOR IMPROVED BY EWOD ACTUATOR-BASED MICROFLUIDIC CHIP | en_US |
dc.type |
Article | en_US |
檔案
本條目沒有附加檔案。
所屬典藏: 期刊論文
引用此條目
Liu, C.-W., Lin, C.-C., Chen, L.-C., Fan, S.-K., & Chang, H.-C. (2009). AN AFFINITY SENSOR IMPROVED BY EWOD ACTUATOR-BASED MICROFLUIDIC CHIP. BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 21(6), 461–465. https://doi.org/10.4015/S1016237209001659
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/6395