Peak shape and dispersion behavior of solutes in counter-current chromatography with a single phase
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
6795 | en_US |
dc.citation.issue |
40 | en_US |
dc.citation.spage |
6789 | en_US |
dc.citation.volume |
1216 | en_US |
dc.citation.woscount |
0 | |
dc.contributor.author |
Shen, Ching-Wei | en_US |
dc.contributor.author |
Yu, Tiing | en_US |
dc.contributor.department |
應用化學系 | zh_TW |
dc.contributor.department |
Department of Applied Chemistry | en_US |
dc.date.accessioned |
2014-12-08T15:08:33Z | |
dc.date.available |
2014-12-08T15:08:33Z | |
dc.date.issued |
2009-10-02 | en_US |
dc.description.abstract |
The dispersion behavior of solutes was investigated in a rotating flowing coiled tube. Potassium iodide, tartrazine, ascorbic acid, lysozyme, bovine serum albumin (BSA), and silver nanoparticle (AgNPs) samples were eluted in a coiled tube of counter-current chromatography (CCC) apparatus with a single phase. Apparent convection peaks of low-diffusivity Solutes appeared in the static CCC tube, while Gaussian-like peaks showed Up for the high-diffusivity solutes. When the rotation speed of the CCC apparatus was elevated, all solute peak widths became smaller, and the convection peaks of AgNPs and BSA were minimized and formed Gaussian-like peaks. The axial dispersions of all solutes were reduced owing to the higher radial mass transfer in the rotating CCC column. The same reasoning could also be used to rationalize other special band shapes encountered in two-phase CCC separations. (C) 2009 Elsevier B.V. All rights reserved. | en_US |
dc.identifier.doi |
10.1016/j.chroma.2009.08.010 | en_US |
dc.identifier.issn |
0021-9673 | en_US |
dc.identifier.journal |
JOURNAL OF CHROMATOGRAPHY A | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1016/j.chroma.2009.08.010 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/6576 | |
dc.identifier.wosnumber |
WOS:000270317500002 | |
dc.language.iso |
en_US | en_US |
dc.subject |
Counter-current chromatography | en_US |
dc.subject |
Dispersion | en_US |
dc.subject |
Diffusion | en_US |
dc.subject |
Wide-bore hydrodynamic chromatography | en_US |
dc.subject |
Nanoparticles | en_US |
dc.subject |
Rotational coiled tube | en_US |
dc.subject |
Convection peak | en_US |
dc.title |
Peak shape and dispersion behavior of solutes in counter-current chromatography with a single phase | en_US |
dc.type |
Article | en_US |
檔案
- 000270317500002.pdf (802.5 KB, Adobe PDF)
所屬典藏: 期刊論文
引用此條目
Shen, C.-W., & Yu, T. (2009). Peak shape and dispersion behavior of solutes in counter-current chromatography with a single phase. JOURNAL OF CHROMATOGRAPHY A, 1216(40), 6789–6795. https://doi.org/10.1016/j.chroma.2009.08.010
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/6576