Miniaturized metal semiconductor metal photocurrent system for biomolecular sensing via chemiluminescence
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
3197 | en_US |
dc.citation.issue |
18 | en_US |
dc.citation.spage |
3189 | en_US |
dc.citation.volume |
30 | en_US |
dc.citation.woscount |
7 | |
dc.contributor.author |
Lin, Chie-Chieh | en_US |
dc.contributor.author |
Ko, Fu-Hsiang | en_US |
dc.contributor.author |
Chen, Chun-Chi | en_US |
dc.contributor.author |
Yang, Yuh-Shyong | en_US |
dc.contributor.author |
Chang, Feng-Chi | en_US |
dc.contributor.author |
Wu, Chung-Shu | en_US |
dc.contributor.department |
材料科學與工程學系 | zh_TW |
dc.contributor.department |
生物科技學系 | zh_TW |
dc.contributor.department |
Department of Materials Science and Engineering | en_US |
dc.contributor.department |
Department of Biological Science and Technology | en_US |
dc.date.accessioned |
2014-12-08T15:08:48Z | |
dc.date.available |
2014-12-08T15:08:48Z | |
dc.date.issued |
2009-09-01 | en_US |
dc.description.abstract |
A miniaturized metal semiconductor metal photodetector was developed as the core detector for chemiluminescence biosensor. The biosensor utilized the semiconductor manufacturing to fabricate the 83 interdigitated patterns of 250-nm metal line and 278-nm space in 100 mu m x 100 mu m active region. The established real-time detector was operated at 0.4 V to ensure the maximal signal to background ratio of 3600 under illumination intensity of 1.46 mW/cm(2). A chemiluminescence in the miniaturized chamber was successfully proposed to determine the model protein concentration in real-time analysis. Before the emission of light from the catalytic reaction of substrate, the model protein of streptavidin bound to horseradish peroxidase was successfully immobilized onto the sensor surface through the high-affinity conjugate with biotin. The detection limit of 4.76 nM for streptavidin analysis was obtained under the calibration curve of linear range over 5-100 nM with correlation coefficient of 0.9999. | en_US |
dc.identifier.doi |
10.1002/elps.200900120 | en_US |
dc.identifier.issn |
0173-0835 | en_US |
dc.identifier.journal |
ELECTROPHORESIS | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1002/elps.200900120 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/6728 | |
dc.identifier.wosnumber |
WOS:000270446200011 | |
dc.language.iso |
en_US | en_US |
dc.subject |
Biosensor | en_US |
dc.subject |
Chemiluminescence | en_US |
dc.subject |
Metal semiconductor metal photodetector | en_US |
dc.subject |
Model protein analysis | en_US |
dc.title |
Miniaturized metal semiconductor metal photocurrent system for biomolecular sensing via chemiluminescence | en_US |
dc.type |
Article | en_US |
檔案
- 000270446200011.pdf (425.2 KB, Adobe PDF)
所屬典藏: 期刊論文
引用此條目
Lin, C.-C., Ko, F.-H., Chen, C.-C., Yang, Y.-S., Chang, F.-C., & Wu, C.-S. (2009). Miniaturized metal semiconductor metal photocurrent system for biomolecular sensing via chemiluminescence. ELECTROPHORESIS, 30(18), 3189–3197. https://doi.org/10.1002/elps.200900120
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/6728