Application of Pd/Ge/Cu alloyed ohmic contact system to n-type GaAs for fully Cu-metallized InGaP/GaAs HBTs
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
159 | en_US |
dc.citation.issue |
2 | en_US |
dc.citation.spage |
154 | en_US |
dc.citation.volume |
53 | en_US |
dc.citation.woscount |
1 | |
dc.contributor.author |
Chen, Ke-Shian | en_US |
dc.contributor.author |
Chang, Edward Yi | en_US |
dc.contributor.author |
Lin, Chia-Ching | en_US |
dc.contributor.author |
Lee, Cheng-Shih | en_US |
dc.contributor.department |
材料科學與工程學系 | zh_TW |
dc.contributor.department |
Department of Materials Science and Engineering | en_US |
dc.date.accessioned |
2014-12-08T15:10:02Z | |
dc.date.available |
2014-12-08T15:10:02Z | |
dc.date.issued |
2009-02-01 | en_US |
dc.description.abstract |
Use of the Pd/Ge/Cu multilayers as the emitter and collector ohmic metal for the fully Cu-metallized InGaP/GaAs heterojunction bipolar transistors is studied. The Pd/Ge/Cu ohmic contact exhibited a very low contact resistance of 5.73 x 10(-7) Omega cm(2) at a low annealing temperature (250 degrees C) and the microstructure evolution of Pd/Ge/Cu ohmic contact was investigated using transmission electron microscopy and energy dispersive spectrometer. We also did some comparisons between the Pd/Ge/Cu, Pd/Ge/Ti/Pt/Cu, and the traditional Au/Ge/Ni/Au ohmic contact structures to n-type GaAs. The common emitter I-V curves and Gummel plot of these Cu-metallized HBTs using Pd/Ge/Cu ohmic contact and Cu interconnects showed similar electrical characteristics as those HBTs with conventional Au-metallization. The cutoff frequency (f(T)) of 3 x 20-mu m-emitter-area devices was about 38 GHz. During both the current-accelerated stress test (110 kA/cm(2) stress for 24 h) and the thermal stability test (annealing at 250 degrees C for 24 h), the fully Cu-metallized HBT with Pd/Ge/Cu ohmic contact and Cu interconnects showed almost no obvious degradation in electrical characteristics. The results show that the Pd/Ge/Cu ohmic contact in combination with the Cu interconnects can be used on HBT devices to achieve the Au-free fully Cu-metallized lnGaP/GaAs HBTs, and the devices exhibit good device performance. (C) 2008 Elsevier Ltd. All rights reserved. | en_US |
dc.identifier.doi |
10.1016/j.sse.2008.10.017 | en_US |
dc.identifier.issn |
0038-1101 | en_US |
dc.identifier.journal |
SOLID-STATE ELECTRONICS | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1016/j.sse.2008.10.017 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/7666 | |
dc.identifier.wosnumber |
WOS:000263596100009 | |
dc.language.iso |
en_US | en_US |
dc.subject |
Copper | en_US |
dc.subject |
GaAs | en_US |
dc.subject |
HBT | en_US |
dc.subject |
Metallization | en_US |
dc.subject |
Ohmic contact | en_US |
dc.title |
Application of Pd/Ge/Cu alloyed ohmic contact system to n-type GaAs for fully Cu-metallized InGaP/GaAs HBTs | en_US |
dc.type |
Article | en_US |
檔案
- 000263596100009.pdf (685.3 KB, Adobe PDF)
所屬典藏: 期刊論文
引用此條目
Chen, K.-S., Chang, E. Y., Lin, C.-C., & Lee, C.-S. (2009). Application of Pd/Ge/Cu alloyed ohmic contact system to n-type GaAs for fully Cu-metallized InGaP/GaAs HBTs. SOLID-STATE ELECTRONICS, 53(2), 154–159. https://doi.org/10.1016/j.sse.2008.10.017
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/7666