Effects of recycling-sludge operation on the structure and moisture content of floc in water treatment plant
Files
- A1997YL15600008.pdf (441.1 KB, Adobe PDF)
Date
1997
Type
Department
Journal Title
SEPARATION SCIENCE AND TECHNOLOGY
Volume, issue and pages
Vol. 32, No. 17, pp. 2873–2882
ISSN
0149-6395
Language
English
Abstract
Recycling-sludge operation is applied in the Feng-Yuan Water Treatment Facility to treat low turbidity source water. By employing fractal dimension analysis and the dilatometry technique, the effects of recycling-sludge operation on the structure and moisture content of sludge flocs are studied. As the results show, the recycling-sludge operation can decrease the average bound water content by nearly 13-24% and increase the effective flee density, thereby forming a compact structure with a high fractal dimension and low flee porosity. The results also indicate that a significant correlation arises between the fractal dimensions and the bound water content of the sludge flocs.
Collections
ArticlesCite this item
Wu, C., & Huang, C. (1997). Effects of recycling-sludge operation on the structure and moisture content of floc in water treatment plant. SEPARATION SCIENCE AND TECHNOLOGY, 32(17), 2873–2882. https://ir.lib.nycu.edu.tw/handle/11536/809